power-Up

When power is applied to the gauge, the display will light up with all eights immediately followed by the gauge firmware version. After the
firmware version is momentarily displayed, the gauge will begin normal operation and display real time sender readings.

12 mONTH LImITeD WARRANTy

Auto Meter Products, Inc. warrants to the consumer that all Auto Meter High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the
original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at Auto Meter’s option to the consumer, when it is determined by Auto Meter Products, Inc. that the product
failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Auto Meter instruments. In no event shall this warranty exceed the original purchase price of
the Auto Meter instruments nor shall Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Auto Meter
must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in
duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Auto Meter
Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter.

FOR SERVICE SEND TO:

AUTO meTeR pRODUCTS, INC. 413 W. Elm St., Sycamore, IL 60178 USA (815) 899-0801

Email us at [email protected]

http://www.autometer.com

2650-1240-00 5/17/07

pROBe INSTALLATION

1. Begin by installing the Thermocouple in the exhaust, then work back to the gauge. For turbo engines, install the probe 1-2
inches from the turbo exhaust outlet or you may install the probe prior to the turbo. You may consult an engine builder or
tuner for recommendations for which probe location is best for you. If installing pre-turbo, removal of the pipe or manifold may
be necessary to avoid metal shavings in the turbo. For non-turbo engines, install the probe 1-2 inches from the cylinder head.
A)

1

/

8

" NPT Threaded Hole: Simply screw the threaded fitting into the hole, insert the probe, and tighten the set

screw snugly onto the probe. (Caution: do not over tighten set screw or damage to probe may occur.) Make sure the probe is

oriented so the wires do not come in contact with, or become too close to the manifold or other hot engine parts.

See illustration for details.

B) Stainless Clamp Method: This method is for applications that require frequent removal of the manifold or header for service,

or just faster and easier installation. Drill a

7

/

16

" diameter hole about 6” down from the junction of the exhaust pipe to manifold

junction. Undo the clamp and slide the probe into the hole in the clamp. Slide the set screw collar onto the probe.

Before tightening the collar in position make sure that when inserted, the probe will have it’s tip in the middle two-thirds of the

exhaust stream. Tighten screw collar in position. (Caution: do not over tighten set screw or damage to probe may occur.)

Hold the clamp open when inserting the probe into the

13

/

32

" hole. Re-join the clamp ends and tighten in position.

Make sure the probe is oriented so the wires do not come in contact with, or become too close to the manifold or other hot

engine parts. See the illustration below for details.

2. With the probe installed, the wire harness can now be routed to the gauge. The wire harness is an integral part of the pyrometer
calibration. It may not be shortened or lengthened without affecting the gauge calibration. You will need to determine a suitable
location to coil the excess wire, and tie it loosely with a wire tie. (Loosely tying the excess coil prevents embritlement caused by
vibration.) Pass the harness through the fire wall using an existing hole, or drill a 1” diameter hole and use the rubber grommet
provided to protect the wire from damage.

PROBE

SET SCREW

COLLAR

STAINLESS

CLAMP

middle 2/3

A. 1/8" NpT Threaded Hole or Drill & Tap into manifold (D)

B. Stainless Clamp method

© 2007 Auto Meter Products, Inc.

The Super Bezel is a registered trademark of Auto Meter Products, Inc.

SeRVICe

For service send your product to Auto Meter in a well packed shipping carton. Please include a note explaining what the problem is along with your phone number. Please specify when you need
the product back. If you need it back immediately mark the outside of the box “RUSH REPAIR,” and Auto Meter will service product within two days after receiving it. ($10.00 charge will be added
to the cost of “RUSH REPAIR.”) If you are sending product back for Warranty adjustment, you must include a copy (or original) of your sales receipt from the place of purchase.

Drill

5

16

" letter R (.339)

Hole and tap for

1

8

"

NPT

in cast exhaust manifold
collector or other engine
builder specified location.