Lighting mode, Gauge reset, Data logger output – Auto Meter 5640 User Manual

Page 3: Pro control active states

Advertising
background image

Lighting Mode

(Region B Color)
This gauge allows the dial lighting to operate in two modes, Full On or Dimmable. Factory default is Full On.

full On:

In this mode, the white lighting wire is ignored. The gauge dial lighting is always on at full brightness. (unless you select NO color

when setting the Backlight Color). If using Full On mode, white wire hook-up is not needed.

dimmable: In this mode, the white wire is used to set the intensity of the dial lighting from full brightness down to off.

To change the Lighting Mode:

With power off, press and hold the pEAK button. Apply power to the gauge. Release the pEAK button and the dial face will illuminate with

either white lighting or blue lighting. Press and release the PEAK button to toggle between Full On (dial is illuminated white) and Dimmable

(dial is illuminated blue). Once you have selected the desired mode, don’t press any buttons for about three seconds. The dial will flicker white

several times to indicate the desired setting has been saved and the gauge will return to normal operation with your new mode selection. Mode

selections are saved when power is off.

NOTE: The Pro Control Active State does not

affect the color of each dial region.

(Back of Gauge)

Ground Neg (-)
(Black)

Sensor Signal (+)
(Yellow)

5 4 3 2 1

10 9 8 7 6

It may be desired to reset the gauge. This clears programmable

settings to a system default. With power off, hold in both buttons.

Apply power to the gauge, wait two seconds, and release both buttons.

The dial face will flicker white several times and return to normal

operation. At this point, the gauge has been reset.
Reset Settings:
High Warning Set Point: Max Value

Low Warning Set Point: Lowest Value

Peak: Lowest Value

High Warning Color: Red

Low Warning Color: Green

Backlighting Color: White

Lighting Mode: Full On

High Warning Pro Control State: Active High

Low Warning Pro Control State: Active Low

High Over Warn Set Point: Max Value

Low Over Warn Set Point: Lowest Value

The active region for Pro Control outputs are user configurable. For

example, consider a pressure gauge with a low warning set point at

20 PSI . The gauge can be configured so the associated Pro Control

output is active when the pointer falls below the set point [less than 20

PSI] (active low) OR when the pointer is beyond the set point [greater

than 20 PSI] (active high). Likewise, consider a pressure gauge with

high warning set point at 95 PSI. Again, the gauge can be configured

so the associated Pro Control is active when the pointer falls below

the set point [less than 95 PSI] (active low) OR when the pointer

progresses beyond the set point [greater than 95 PSI] (active high).

To change the active state:

With power off, press and hold the pEAK button. Apply power to the

gauge. Release the pEAK button. Press and release the wARN

button. The gauge is now in Active State Set Mode. The pointer will

point straight up at the value in the top center of the dial. Press and

release the wARN button to toggle back and forth between the low and

high warning point active state modes. Doing so will cause the dial to

change back and forth between green and red. When setting the low

warning active state the dial face will be green. When setting the high

warning active state the dial face will be red.

Once the designated warning mode is selected (green or red) press and

hold the wARN button to toggle between active high and active low. As

you hold the button the pointer will continuously sweep from the left of

center and to the right of center pausing at each side. Left of center is

active low and right of center is active high. Release the wARN button

when the pointer is in the position of the desired active state. Once you

have selected the desired state, don’t press any buttons for about three

seconds. The dial will flicker white several times to indicate the desired

setting has been saved and the gauge will return to normal operation

with your new state selection. State selections are saved when power is

off.

gauge Reset

Data Logger CaLibration Chart

Temp (F)

DL Vout

N

Temp (F) DL Vout

N

Point 1

60

0.510

418

Point 10

200

3.333

2730

Point 2

80

0.791

648

Point 11

220

3.662

3000

Point 3

100

1.174

962

Point 12

240

3.937

3225

Point 4

120

1.594

1306

Point 13

250

4.056

3323

Point 5

130

1.810

1483

Point 14

260

4.155

3404

Point 6

140

2.030

1663

Point 15

280

4.342

3557

Point 7

160

2.507

2054

Point 16

310

4.535

3715

Point 8

180

2.938

2407

Point 17

340

4.668

3824

Point 9

190

3.145

2576

data Logger Output

This gauge is equipped to output the sensor signal to an external data logger system. This feature allows you to use the same sensor for both the

gauge and the data logger. With this gauge, it is not necessary to install two sensors to measure the same function.

To use this feature, you must have a data logger system installed in the vehicle and connect the data logger output from the gauge to the data

logger. Pins number 4 (black wire, ground) and 8 (yellow wire, sender signal) in the connector on the back of the gauge are the data logger sensor

signal and ground connections that must be connected to the data logger. After connecting the gauge to the data logger, refer to your data logger

instruction on how to calibrate the data logger to use the signal.

Quick Calibration:
Use the voltage in the ‘DL Vout’ column to calibrate your data logger over the desired temp range.

Calibration For More Accuracy:
Follow these steps to obtain a more accurate calibration.
On the side of the gauge is a label that reads ‘Data
Logger = x.xxx’ where x.xxx is a number.
This number is Vs in the following equation.

DL Vout = N x Vs / 4096

pro Control Active States