INSTALLATION INSTRUCTIONS

fULL Sweep eLeCTRIC

VOLT MeTeR

2650-1135-00 Rev. B

power-Up

The pointer will move backward to the stop pin and then display the correct voltage. This procedure is an auto-calibration function and is

performed on every power-up. While this test is being performed, the gauge may make a clicking sound. This is normal.

CAUTION!

As a safety precaution, the +12V terminal

of this product should be fused before

connecting to the 12V ignition switch. We

recommend using a 1 Amp, 3AG fast-acting

type cartridge fuse

(Littlefuse® # 312 001 or an equivalent).

Installation

1. Check that you have all parts required for installation.

2. Disconnect the negative (-) battery cable.

3. Gauge mounts in a 2

1

16

” hole. Use supplied

brackets and nuts to secure to dash.

4. Attach black wire from harness to good engine ground.

5. Attach red wire from harness to +12V terminal on

ignition switch or other +12V power source. Use a

switched power source.

6. Attach white wire to dash lighting or switchable

+12V light source.

7. Reconnect negative (-) battery cable.

12 MONTH LIMITeD wARRANTY

Auto Meter Products, Inc. warrants to the consumer that all Auto Meter High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the

original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at Auto Meter’s option to the consumer, when it is determined by Auto Meter Products, Inc. that the product

failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Auto Meter instruments. In no event shall this warranty exceed the original purchase price of

the Auto Meter instruments nor shall Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Auto Meter

must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in

duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Auto Meter

Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter.

SeRVICe

For service send your product to Auto Meter in a well packed shipping carton. Please include a note explaining what the problem is along with your phone number. Please specify when you

need the product back. If you need it back immediately mark the outside of the box “RUSH REPAIR,” and Auto Meter will service product within two days after receiving it. ($10.00 charge will be

added to the cost of “RUSH REPAIR.”) If you are sending product back for Warranty adjustment, you must include a copy (or original) of your sales receipt from the place of purchase.

FOR SERVICE SEND TO: AUTO MeTeR pRODUCTS, INC. 413 W. Elm St., Sycamore, IL 60178 USA (815) 899-0801

Email us at [email protected]

http://www.autometer.com

2650-1135-00 Rev. B 11/09/07

© 2007 Auto Meter Products, Inc

The Super Bezel is a registered trademark of Auto Meter Products, Inc.

12V BATTeRY

GOOD

ENGINE

GROUND

+ 12v

CONNECTION

RED

BLACK

FUSE

(SEE CAUTION BELOW)

+12v DASH

DO NOT HOOK TO ALTeRNATOR

WHITE

GOOD

ENGINE

GROUND

+12v

DASH

LIGHTING

(for standard incandescent

lit instrument)

BLACK

FOR INTERNAL LED

LIT INSTRUMENTS

WHITE

for model with warning light and peak recall

To adjust the warning set point, momentarily press and release the WARN button. The warning light will begin to flash and the pointer will

move to the previous set point signifying that warning set mode has been selected. Once in set mode, press the WARN button to move the

pointer down, or press the PEAK button to move the pointer up. Warning set points can only be set in the voltage range. Three seconds

after the last button press, the warning light will stop blinking and the pointer will return to the current voltage reading. The warning set point

is retained when power is removed from the gauge.

warning Indicator

peak Recall

Press and hold the PEAK button to recall the highest voltage reading since the memory was last cleared. To clear the memory, press and

hold the PEAK button, and while still holding the PEAK button, press the WARN button. The pointer will move to Stop Peg to indicate that

the memory has been cleared. Release the PEAK and WARN buttons to resume normal operation. The peak recall point is retained when

power is removed from the gauge.