Axcess Flex Antenna Quick Start User Manual

Ff ll ee xx aa nn tt ee nn nn aa, Quick start

Advertising
background image

Installation Overview

3208 Commander Drive, Carrollton,
Texas 75006
800.588.6080 / FAX: 972.407.9085
technical support: 800.577.6080
www.axcessinc.com

Quick Start

Quick Start

Set Up & Installation

Flex Antenna

Required Materials

1

1

Receiver

Device (PC, Wiegand

control panel, etc.)

Supplied 20 Foot Lead

Ÿ

RG-58/U coaxial cable with 50 ohm impedance (nominal),
solid copper center conductor, 55% tinned copper braid
or better, 100% shield coverage (i.e. Belden 9310) of
sufficient length to reach the Activator.

The maximum

recommended cable length is 50 feet.

Have the following materials on hand for the installation
of the Flex Antenna:

To ensure proper system operation,

do not substitute

antenna kit components.

Determine the approximate installation site of the Flex Antenna
and its associated Activators. Use the following guidlines:

Installation Considerations

2

2

Ÿ

The Activator should be located no more than

50 feet

(cable length) from the Flex Antenna.

Ÿ

The Plex Antenna's field is affected by metal; therefore,
the Antenna and should be located at least

4 inches

from any metal including metal studs.

The

Flex Antenna is a thin and flexible activation

antenna that is very versitle and has numerous
mounting options: under carpet, behind pictures,
within walls or overhead.

Activator Placement

Flex Antenna Placement

Activator

Tag

Flex Antenna

FF

ll

ee

xx

AA

nn

tt

ee

nn

nn

aa

A

A

Ÿ

Two three-piece crimp type male BNC connectors

Ÿ

Three-blade rotary coaxial cable stripper

Ÿ

Step ladder for positioning the Flex Antenna above the door
or ceiling

Choose the mounting position best suited for
the desired coverage area and application.
(See diagram below)

Maximum distance between
Activator and Antenna:

50 feet

Activator

(Above
Ceiling)

Check with all local inspection codes, including building,
fire and electrical, to ensure compliance of the Flex
Antenna installation.

Before permanently installing the Flex Antenna, lay out
and test the entire ActiveTag system.

Refer to the
Configuration
Guide for
preferred antenna
placement of asset
and personnel
tracking applications.

Metal Door Frame

4"

Minimum distance from
any metal:

4 inches

4"

Behind a non-metallic

picture frame

3rd Choice

Under carpet or

floor covering

1st Choice

Above ceiling

4th Choice

4"

Metal Stud

Within a wall

2nd Choice

!!

!!

750.010.005