Gas Pressure Fryer

Operation

Operation After Gas or Power Outage

The fryer may shut off automatically if the gas supply is interrupted or the power goes out. If either of these
conditions occur you should perform the following procedure:

For your safety, if the gas supply stops, or, if the power goes out, make sure to wait for at
least five minutes before restarting your fryer. This allows time for any unburned gas to
dissipate. (LP gas may take longer than five minutes.) If you smell gas, do not start your
fryer.

1. Place the gas control ON/OFF switch in the OFF position.

2. Place

the

FILTER/OFF/FRY switch in the OFF position.

3. Wait at least five minutes to allow any gas that may have accumulated in the burner compartment to

escape.

4. Follow normal operating procedures once the power or gas is restored.

Normal Shutoff

1. Place

the

FILTER/OFF/FRY switch in the OFF position.

2. Place the gas control ON/OFF switch in the OFF position.

3. Wait at least five minutes to allow any gas that may have accumulated in the burner compartment to

escape.