Troubleshooting, Computer hangs – BKI LGF-FC Gas Pressure Fryer User Manual
Page 40
Gas Pressure Fryer
Maintenance
38
Troubleshooting
Refer to the table below for troubleshooting information.
Problem Cause
Possible
Solution
Pressure Loss or Not Releasing
Pressure
Dead Weight Valve Leaking
Clean the weight and orifice. If problems
persist, contact an authorized BKI service
agent for corrective action.
Lid Gasket Leaking
Contact an authorized BKI service agent
for corrective action.
Solenoid Valve Leaking or
Stuck
After a period of time, it is possible that
the valve seat and/or plunger may stick or
wear. Activate the valve by starting a cook
cycle. You should hear a solid metallic
CLICK sound from the solenoid valve. If
you should hear no sound (or a slow
BUZZING CLICK), contact an authorized
BKI service agent for corrective action.
Safety Valve not seating
Contact an authorized BKI service agent
for corrective action.
Shortening Heating Too Slowly
Gas pressure is low or isn’t
adjusted properly
Contact an authorized BKI service agent
for corrective action.
Bad thermostat or loose
wires
Contact an authorized BKI service agent
for corrective action.
Filter System Not Working
Uncertain
Press the reset button on end of pump
and hi-limit reset button under control
panel. If problems persist, contact an
authorized BKI service agent for
corrective action.
Connections not tight
Tighten the connections. If problems
persist, contact an authorized BKI service
agent for corrective action.
Filter valve not open
Contact an authorized BKI service agent
for corrective action.
Filter paper on screen
clogged with crumbs
Change filter paper. If problems persist,
contact an authorized BKI service agent
for corrective action.
Motor hums, but does not
pump
Check for clogged pump. If problems
persist, contact an authorized BKI service
agent for corrective action.
Motor and pump coupling
worn
Contact an authorized BKI service agent
for corrective action.
No power to control panel
Make sure drain valve is completely
closed. If problems persist, contact an
authorized BKI service agent for
corrective action.
Computer Hangs
Computer malfunction.
Press and hold the Toggle/Clear button
while moving the FRY/OFF/FILTER
switch from FRY to OFF and back to
FRY. If problems persist, contact an
authorized BKI service agent for
corrective action.