Maintenance

Maintenance

Failure to comply with the maintenance below could result in a serious accident.

Do not over-tighten the spindle assembly. (Only tighten to hold pressure.)

Your fryer will need periodic maintenance and servicing. We strongly suggest that you
use only a service company that is authorized by BKI to do this work.

The restraining device must always be connected when the appliance is in service.
Disconnect for movement, such as servicing or cleaning. Reconnect the restraint when
fryer has been returned to its normal position.

Scheduled Maintenance

Use the following table to help manage scheduled maintenance activities.

FREQUENCY PERFORMED

BY PART

ACTIVITY

Each Fry Cycle

User

Pressure Gauge

Check for proper display of cooking vat
pressure. Contact authorized BKI service
agent if adjustment or replacement is
required.

User

Lid Gasket

Check for unusual wear such as cracks
and deformation, and pressure leaks.
Contact authorized BKI service agent if
adjustment or replacement is required.

Daily

User Dead

Weight

Assembly

Clean weight and orifices daily and check
for wear.

User

Filter Pad

Replace filter pad. Refer to the procedure
in this manual.

User

Condensation Pan

Remove and drain.

User

Filter system

Filter the shortening using the procedure
in this manual.

Weekly

User

Safety Pop Valve

Check for release of pressure and proper
seal. Refer to the procedure in this
manual.

User

Fryer Pot

Perform the boil-out procedure in this
manual.

Every 6 Months

Authorized BKI
service agent

Acme Screw and
Nut

Check for wear on the threads.

Authorized

BKI

service agent

Solenoid Valve

Check that the valve is holding and
releasing pressure when the timer or
computer activates it.

Authorized

BKI

service agent

Hook, Catch, Spring

Check for wear and ease of operation.

Authorized

BKI

service agent

Connections,
Fittings

Check for leakage while oil is pumping.

Authorized

BKI

service agent

Fryer Pot
Fittings/Connections

Check for leakage around fry pot top deck
and fittings (heaters, hi-limit, thermostat,
etc.).

31