Troubleshooting – BKI FKM-FC Electric Pressure Fryer User Manual

Page 36

Advertising
background image

Electric Pressure Fryer

Maintenance

34

Troubleshooting

Refer to the table below for troubleshooting information.

Problem Cause

Possible

Solution

Pressure Loss or Not Releasing
Pressure

Dead Weight Valve Leaking

Clean the weight and orifice. If
problems persist, contact an
authorized BKI service agent for
corrective action.

Lid Gasket Leaking

Contact an authorized BKI
service agent for corrective
action.

Solenoid Valve Leaking or
Stuck

After a period of time, it is
possible that the valve seat
and/or plunger may stick or wear.
Activate the valve by starting a
cook cycle. You should hear a
solid metallic CLICK sound from
the solenoid valve. If you should
hear no sound (or a slow
BUZZING CLICK), contact an
authorized BKI service agent for
corrective action.

Safety Valve not seating

Contact an authorized BKI
service agent for corrective
action.

Shortening Heating Too Slowly

Low voltage or improper
voltage

Contact an authorized BKI
service agent for corrective
action.

Bad thermostat or loose
wires

Contact an authorized BKI
service agent for corrective
action.

Weak heating elements or
heating elements breaking
down

Contact an authorized BKI
service agent for corrective
action.

Coil on contactor is bad

Contact an authorized BKI
service agent for corrective
action.

Breading build-up on heating
elements

Clean heating elements. If
problems persist, contact an
authorized BKI service agent for
corrective action.

Filter System Not Working

Uncertain

Press the reset button on end of
pump and hi-limit reset button
under control panel. If problems
persist, contact an authorized
BKI service agent for corrective
action.

Connections not tight

Tighten the connections. If
problems persist, contact an
authorized BKI service agent for
corrective action.

Advertising