BKI FKM-FC Electric Pressure Fryer User Manual

Page 25

Advertising
background image

Electric Pressure Fryer

Operation

23

STEP ACTION

DISPLAY

COMMENTS

12

Press TOGGLE/CLEAR until the
desired option is displayed.

PROGRAM VALVE1

X

X refers to the solenoid
valve option selected.
OPEN is used for Models
ALF and BLF Automatic
Lift
fryers. If your program
requires the solenoid valve
to be closed while
cooking, choose the
CLOSED option.

13

Repeat steps 5-12 when
programming stages 2, 3, 4 and
5 for Electric and Gas appliance
types.

Repeat steps 5-10 when
programming stages 2, 3, 4 and
5 for an ALF appliance type.

The time and temperature
of each stage has to be
less than the preceding
stage.

14

Press ENTER.

PROGRAM PREALARM

00:00

This command allows you
to specify the number of
minutes before the end of
the cooking time (for each
stage) until the alarm
sound The prealarm value
displayed may be a
previously programmed
value.

15

Press TOGGLE/CLEAR and
input the prealarm minutes.

PROGRAM PREALARM

XX:XX

XX:XX refers to the
prealarm minutes you
input.

16

Press ENTER.

PROGRAM FILTER

0

This command allows you
to specify the number of
fry cycles you want to
complete for this program
before a message is
displayed reminding you to
filter the shortening (filter
lockout). The filter value
displayed may be a
previously programmed
value.

17

Press TOGGLE/CLEAR and
input the number of fry cycles
you want to complete before
enabling filter lockout.

PROGRAM FILTER

X

X refers to the number of
program cycles you want
to complete before filtering
the shortening.

18

Press ENTER.

PROGRAM PRODUCT #

19

If you wish to input more
programs, proceed by pressing
the next program number and
follow steps 5 through 18 or
press PROG to exit the
programming mode.

Advertising