Maintenance

To refill the pot through the rinse hose, use the steps below:

 Make certain that the rinse hose is connected to rinse hose connector.

 Holding the hose by the handle, place hose nozzle inside the pot.

 Position the FILL lever in the THRU HOSE position.

 Position

the

FILTER/OFF/FRY switch to FILTER and shortening will automatically pump

into the pot.

 Let the filter continue to pump the shortening until the fill mark in the fryer pot is reached

or until air starts bubbling through the shortening.

 As soon as air is seen in the shortening, position the FILTER/OFF/FRY switch to OFF to

prevent shortening degradation.

 Add new shortening if the fill mark has not been reached.

Boil-Out Procedure

Boil-outs remove microscopic particles of carbon that build up on the walls of the fryer pot. To avoid
eventual carbon build-up, off flavors, and shortening breakdown, boil-outs should be done once a week
on each fryer following these procedures.

Always wear appropriate personal protection equipment during the boil-out
process to guard against possible injury from hot cleaning solution.

1. Position

the

FILTER/OFF/FRY switch to OFF.

2. Drain the clean shortening into an adequate storage container. (Allow the shortening to cool to

room temperature before attempting storage.)

3. CLOSE the drain and fill the fryer pot with HOT water to the shortening level fill mark. Do not

overfill by allowing the water level higher than the fill mark.

4. Add ½ cup (4 ounces) of BKI cleaner.

5. Wash down the inside of the pot with the pot brush to loosen the sediment.