Acr installation diagram, Dimensioned drawings, Mini add-a-battery installation diagram – Blue Sea Systems 7601 m-Series Automatic Charging Relay - 12/24V DC 65A User Manual

Page 2: Engines with combined alternator and starter wires

Advertising
background image

start

run

accessory

off

Dual Circuit Plus™ Battery Switch 6011

Included in Mini Add-A-Battery kit,

recommended for 7601

m

-ACR

m

-ACR 7601

COMMON BUS BAR

GROUND

START KEY SWITCH

Engines with

combined alternator

and starter wires

- typical of outboard motors

2

1

House

Start

10A FUSE

16 AWG

16 AWG

OPTIONAL

START ISOLATION

(SI) WIRE

2A FUSE

OPTIONAL SWITCH

FOR NO CURRENT DRAW

WHEN IN STORAGE

Outboard

Accessories

FRONT

BACK - NO COVER

SIDE - NO COVER

2.85"

72.3mm

2.18"

55.2mm

SIDE - WITH COVER

0.38"

9.7mm

0.13"

3.2mm

0.39"

10mm

0.44"

11.1mm

STUD

HEIGHT

0.84"

21.4mm

1.02"

25.8mm

1/4"-20

FRONT PANEL

MOUNT IN

Ø2-5/8" (67mm)

HOLE WITH

MAX. PANEL

THICKNESS

5/16" (8mm)

REAR PANEL

MOUNT IN

Ø2-5/16"

59mm

HOLE

1.84"

46.7mm

2.57"

65.2mm

1.22"

30.9mm

Ø

2.06"

52.2mm

2.85"

72.3mm

2.825"

71.76mm

2.176"

55.27mm

2.825"

71.76mm

2.176"

55.27mm

0.153"

3.87mm

0.310"

7.87mm

1.298"

32.97mm

1.770"

44.96mm

3.068"

77.94mm

0.753"

19.11mm

0.900"

22.86mm

REAR PANEL

MOUNT IN

Ø2-5/16"

59mm

HOLE

FRONT PANEL

MOUNT IN Ø2-5/8"

67mm HOLE

m

-ACR Installation Diagram

Dimensioned Drawings

Mini Add-A-Battery Installation Diagram

425 Sequoia Drive

Bellingham, WA 98226 USA

p 360.738.8230

p 800.222.7617 USA and Canada

f 360.734.4195

[email protected]

www.bluesea.com

10A

FUSE

16 AWG

COMMON BUS BAR

GROUND

OPTIONAL SWITCH

FOR NO CURRENT DRAW

WHEN IN STORAGE

start

run

accessory

off

START KEY SWITCH

OPTIONAL

START ISOLATION

(SI) WIRE

2A

FUSE

Outboard

Accessories

Start

House

m

-ACR 7601

16 AWG

These installation diagrams show typical applications only. Your application may differ.

For further information, please go to www.bluesea.com and navigate to Resources/Application Briefs

and Technical Briefs.

Because the

m

-ACR is dual sensing, the battery connection terminals are interchangeable.

m

-ACR function will not be affected by reversal of the starting and house batteries versus the diagram.

If the status indicator LED is triple-flashing, the

m

-ACR is in a lockout state, and will not combine

batteries until the lockout condition is removed. Ensure neither battery is below 10V for a 12V system

or 20V for a 24V system.

If the status indicator LED is double-flashing, check for positive voltage on the start isolation terminal.

It is recommended that the

m

-ACR be connected directly to your battery positive terminals through

appropriately sized fuses. Connecting in a different location such as a battery switch may affect

accuracy because of voltage drop along current carrying conductors.

If you are not knowledgeable about marine electrical systems,

please consult an electrical professional for help with installation.

If your electrical system is configured with a charging source that cannot supply

the full load current being drawn from the batteries, open/close cycling

can occur. If this cycling continues, the second battery bank

could eventually discharge even though a charge source is present.

See Wire Size and Fuse Rating chart for connections from ACR positive terminals.

Note: To determine wire sizes and fuse ratings for all other wires illustrated, please visit

the Circuit Wizard at circuitwizard.bluesea.com

m

-Series, Dual Circuit Plus™ Battery Switch 6011

(Included with 7649 Mini Add-A-Battery)

m

ACR, Automatic Charging Relay 7601

Guarantee

Blue Sea Systems stands behind its products for as long as you own them.

Find detailed information at www.bluesea.com/about.

For customer service, call 800-222-7617.

Advertising
This manual is related to the following products: