Blue Sea Systems 7620100B ML-ACR Heavy Duty Automatic Charging Relay 12V [Bulk] User Manual

Overview of application, Ml– series, Marine electrical products

Advertising
background image

PN 7620B / PN 7620100B / PN 7621B / PN 7621100B

(without manual control)

PN 7622B / PN 7622100B / PN 7623B / PN 7623100B

(with manual control)

990180610 Rev.002

Blue Sea Systems Inc.

Phone (360) 738-8230

425 Sequoia Drive

Fax (360) 734-4195

Bellingham, WA 98226 USA

www.bluesea.com

• Magnetic Latch (ML)—draws very low current (<10 mA to monitor terminal voltage) in the

ON or OFF states, and draws moderate current for very short time when changing state

• Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during

engine cranking to protect sensitive electronics

• Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect

engine electronics and maximize alternator output

• Senses charging on two battery banks

• LED output to remotely indicate when batteries are combined or isolated

• Tin-plated copper studs for maximum conductivity and corrosion resistance

• Label recesses for circuit identification

• Silver alloy contacts provide high reliability for switching live loads

Specifications

Cranking Rating: 10 sec.

2,500A DC

Intermittent Rating: 5 min.

See Table Below

Continuous Rating

See Table Below

Amperage Operating Current

<40 mA when changing state

Primary Circuit Voltage Rating

32V DC Max.

Relay Contact Position:

-Combine (30 sec.)

13.5V@12V DC | 27.0V@24V DC

-Combine

(90 sec.)

13.0V@12V DC | 26.0V@24V DC

-Open Low (10 sec.)

12.35V@12V DC | 24.7V@24V DC

-Open Low (30 sec.)

12.75V@12V DC | 25.5V@24V DC

-Open High

16.2V@12V DC | 32.4V@24V DC

Live Current Switching

300A@12V DC—10,000 Cycles

Terminal Stud Size

3/8"-16

Maximum Terminal Stud Torque

140 in-lb (15.5 N•m)

Ring Terminal Size

3/8", M10

Terminal Ring Diameter Clearance

1.18” (28.4mm)

Control Circuit Current Draw

<40 mA

Harness Connector: (select models)

Deutsch DTM Series DTM 06-6S

Mating Part Requirements:

(see LADD Industries at www.laddinc.com)

Receptacle Shell

DTM-04-6P*

Wedgelock

WM-6P

Terminal Pins

1060-20-0122†

Sealing Plugs

0413-204-2005†

Hand Crimp Tooling

DTT-20-0‡

Remote Control Switch (sold separately)

Sustained SPDT ON-OFF-ON, Momentary SPDT (ON)-OFF-(ON),

or two momentary push button switches, 100mA rating Min.

Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, Rated IP66
* Special modifications are available depending on customer requirements. No polarization on standard product.

† Quantity depends on optional wire connections. The total number of pins and sealing plugs is 6.

‡ Required for hand assembly of wires and terminal pins.

Marine Electrical Products

PN

Termination

Manual

Control

Control

Circuit

7620B

Tinned Wires

No

12V DC

7620100B Deutsch Connector

No

12V DC

7621B

Tinned Wires

No

24V DC

7621100B Deutsch Connector

No

24V DC

PN

Termination

Manual

Control

Control

Circuit

7622B

Tinned Wires

Yes

12V DC

7622100B Deutsch Connector

Yes

12V DC

7623B

Tinned Wires

Yes

24V DC

7623100B Deutsch Connector

Yes

24V DC

ML– Series

Automatic Charging Relay

(ACR)

Wire Size

Intermittent Rating 5 min.

Continuous Rating

2/0

400 Amps

225 Amps

4/0

400 Amps

300 Amps

2x (4/0)

700 Amps

500 Amps

Guarantee

Blue Sea Systems stands behind its products for as long as you own them.

Find detailed information at www.bluesea.com/about. For customer service, call 800.222.7617.

Overview of Application

The ML-Series ACR automatically combines batteries during charging, and isolates batteries when there is no

charging sensed on either battery bank.

ML-Series ACR Function

12 Volt DC Operation

24 Volt DC Operation

Automatically combines battery

banks when sensed voltage

levels are:

Above 13.5V for 30 sec.

Above 13.0V for 90 sec.

Above 27.0V for 30 sec.

Above 26.0V for 90 sec.

Automatically isolates battery

banks when sensed voltage

levels are:

Below 9.6V (undervoltage lockout)

Below 12.35V for 10 sec.

Below 12.75V for 30 sec.

Above 16.2V (overvoltage lockout)

Below 19.2V (undervoltage lockout)

Below 24.7V for 10 sec.

Below 25.5V for 30 sec.

Above 32.4V (overvoltage lockout)

Start Isolation or Engine Isolation.

The isolation inputs enable one of two functions depending on

how the inputs are configured.

NOTE: The ML-Series ACR can be configured for Start Isolation or Engine Isolation, but not both.

Start Isolation - Temporary isolation (3−5 minutes) of house loads from the engine circuit during engine

cranking to protect sensitive electronics. Configure Start Isolation when there are heavy cranking loads

causing sags and spikes that might damage electronics in the House circuit. See page 3.

Engine Isolation - Isolate two engines while both are running to protect engine electronics, and to

maximize alternator output. Configure Engine Isolation when the engine manufacturer requires it, and

when there are separate batteries for each engine. See page 3.

Undervoltage or Overvoltage Lockout.

• Undervoltage lockout prevents batteries from being combined when either battery is below 9.6V@12V DC

operation or 19.2V@24V DC operation.

• Overvoltage lockout prevents batteries from being combined when either battery is above 16.2V@12V DC

operation or 32.4V@24V DC operation.

Control Switch Remote Operation.

Optional Contura Control Switch—sustained (SPDT) ON-OFF-ON.

The Control Switch should be mounted in a convenient location near helm controls to allow for quick access.

NOTE: Alternatively use a momentary (SPDT) (ON)-OFF-(ON) or momentary push button switch to provide cross connect and/or battery isolation.

To cross connect

(combine) battery banks

Switch to “ON” combines battery banks to provide more battery power in hard

starting situations.

To isolate battery banks

Switch to “OFF”- when the battery banks are isolated using the Control

Switch, the battery banks remain isolated, and for at least 30 seconds after

the control switch is returned to the “AUTO” position.

Control Switch Remote Indication or ML-ACR Status

NOTE: The remote switch has two LEDs (top and bottom). These LEDs operate simultaneously-either they are both ON or both OFF.

page 1 of 4

LED INDICATION

ACR STATE OR CONDITION

Remote Switch Set to “AUTO” or no Remote Switch Installed
LEDs OFF

Batteries are isolated

LEDs ON

Batteries are combined

LEDs slow steady blink, ON-OFF

Start or Engine Isolation is causing batteries to be isolated

LEDs quick steady blink, ON-OFF

Undervoltage lockout--either battery is below 9.6V@12V DC

operation or 19.2V@24V DC operation.

Overvoltage lockout--either battery is above 16.2V@12V DC

operation or 32.4V@24V DC operation.

Remote Switch Set to OVERRIDE “ON” or “OFF”—Automatic operation is suspended for 10 minutes

after remote switch is returned to “AUTO”
LEDs double blink,

Blink-Blink-Pause, Repeat

Manual override--check ACR for switch states

OR

ACR mechanical failure