Specifications are subject to change. See bluesea.com/P12 for current information.

* Consult battery manufacturer specifications for other battery types to avoid damage. Do not mix battery types.
** Battery bank sizes are recommended for optimal charging efficiency-see bluesea.com/P12 for details. Larger and smaller size banks could charge well, but consume slightly
more power over the charging cycle.

Regulatory

Designed and constructed for compliance to UL-1236 Marine, CSA 22.2 No. 107.2, and ABYC A-31 standards. Ignition Protection per ISO 8846, and SAE J1171.
Meets FCC Part 15, Class B requirements. To view current regulatory specifications visit www.bluesea.com/P12.

Specifications

7521

7522

Total Output Current

25A

40A

Input AC Current

4.5A @ 100V AC / 2.25A @ 200V AC

7.5A @ 100V AC / 3.75A @ 200V AC

Nominal Output Voltage

12V DC

12V DC

Output Connections

3 positive, 1 negative

3 positive, 1 negative

Universal AC Input Voltage

90V–265V AC

90V–265V AC

Input Frequency Range

45–65 Hz

45–65 Hz

Typical Float Voltage

13.5V DC

13.5V DC

Maximum Available Voltage

16.0V DC

16.0V DC

Output Voltage Accuracy

0.05V DC

0.05V DC

Minimum Operating Temperature

−20°C (−4°F)

−20°C (−4°F)

Maximum Operating Temperature

70°C (158°F)

70°C (158°F)

Minimum Storage Temperature

−30°C (−22°F)

−30°C (−22°F)

Maximum Storage Temperature

80°C (176°F)

80°C (176°F)

Warranty

5 Year

5 Year

Battery Types*

Flooded, Gel, AGM, TPPL

(Thin Plate Pure Lead)

Flooded, Gel, AGM, TPPL

(Thin Plate Pure Lead)

Recommended for Battery Bank Sizes**

160Ah Minimum,

Example: 2 x Group 27

330Ah Maximum,

Example: 3 x Group 31

220Ah Minimum,

Example: 2 x Group 31

440Ah Maximum,

Example: 4 x Group 31

Conductor Length in feet (meters)

Charger Rating

25A

40A

6 ft (1.83 meters)

14 AWG (2.5mm²)

8 AWG (10mm²)

10 ft (3.05 meters)

12 AWG (4mm²)

8 AWG (10mm²)

15 ft (4.57 meters)

10 AWG (6mm²)

6 AWG (16mm²)

20 ft (6.09 meters)

8 AWG (10mm²)

6 AWG (16mm²)

25 ft (7.62 meters)

6 AWG (16mm²)

4 AWG (25mm²)

Recommended Battery Fuse

30A

60A

Region

Line

Neutral

Ground (Earth)

North America

Black

White

Green

Europe

Brown

Blue

Green-Yellow

Australia/ New Zealand

Brown or Red

Blue or Black

Green-Yellow

Table A: Minimum Recommended Wire Size*

Appropriate Fuses and Fuse Holders

Charger Rating

Fuse Type

Fuse Holder

25A

40A

MRBF Terminal Fuses

5191 Terminal Fuse Block

5175 (30A Fuse)

5178 (60A Fuse)

AMI®/MIDI® Fuses

7720 Safety Fuse Block

5250 (30A Fuse)

5253 (60A Fuse)

Table B: Recommended DC Circuit Protection

Table C: Typical AC Regional Wire Colors

Table D: AC Wire - Circuit Protection Selection Chart

7521

(25A)

7522

(40A)

Input Watts

450

750

120V AC Application

4.5A @ 100V AC

7.5A @ 100V AC

Minimum AC Wire Size

18 AWG (0.75mm²)

16 AWG (1.5mm²)

Circuit Breaker

10A

15A

230V AC Application*

2.25A @ 200V AC

3.75A @ 200V AC

Minimum Wire Size

18 AWG (0.75mm²)

18 AWG (0.75mm²)

Circuit Breaker

5A – 10A

5A – 10A

* Typical of Europe

Type

Absorb Volts

Float Volts

FLA – Flooded Lead Acid

14.5V

13.5V

AGM – Absorbed Glass Mat

14.35V

13.3V

Gel – Gelled Electrolyte

14.1V

13.5V

TPPL – Thin Plate Pure Lead

14.7V

13.6V

¹

User Adjustable

12.5V

Default

12.5V

Default

¹

Taken from Odyssey Tech Notes, Northstar operation Manual

Table E: Default Voltages by Battery Type

Batteries should match in chemistry, although many AGM’s and flooded batteries are
compatible. Based on 25°C (77°F)

5

* Based on 3% voltage drop. If fast charge recovery is important, use larger wire. Double the conductor
length entry to get a 1.5% drop, triple the conductor length to get a 1% voltage drop.

P12

7521 AND 7522 BATTERY CHARGERS

Advertising