PN 7725 / PN 7725B

PN 7725 includes a connector plug for the ATO

®

/ATC

®

fuse circuits


The Blue Sea Systems SafetyHub 100 is an ignition-protected fuse block
with an integrated connecting plug. It consolidates 1A

200A fuses, and can

be wired directly to the battery (for unswitched fuse protection) or after the
battery switch (for switched fuse protection).

]

Disconnect all battery connections before beginning the installation.

]

Blue Sea Systems strongly recommends that a competent electrical

professional perform the installation of this product.

GUARANTEE: Blue Sea Systems stands behind its products

for as long as you own them. Find detailed information at

www.bluesea.com/about. For customer service, call 800-222-7617.

Marine Electrical Products

SafetyHub 100 Fuse Block

Blue Sea Systems Inc.

p 360.738-8230

425 Sequoia Drive

f 360.734-4195

Bellingham, WA 98226 USA

[email protected]

www.bluesea.com

980004720 Rev.004

Specifications

WARNING

Amperage Maximum Operating (combined)

(see table below)

Nominal Operating Voltage

12V DC

Minimum Input Cable Size to Meet Ratings

4/0 AWG (120 mm²)

Recommended Ring Terminal

M8 (5/16”)

Stud Size

M8 x 1.25

Stud Torque

15 ft-lb (20.3 N-m)

AMI

®

/MIDI

®

Fuse Block

Amperage Maximum Operating (per block)

240A†

Amperage Maximum Operating (per circuit)

170A†

Fuse Amperages Available

30A–200A

Minimum Cable Size to Meet Ratings

2/0 AWG (70 mm²)

Screw Size

M5 x .8 x 10

Screw Torque

27 in-lb (3.0 N-m)

ATO

®

/ATC

®

Fuse Block

Amperage Maximum Operating (per block)

50A†

Amperage Maximum Operating (per circuit)

20A†

Fuse Amperages Available

1A–20A

Regulatory

E

marked

Meets ISO 8846 ignition protection and SAE J1171 external ignition protection requirements.

IP66—protected against powerful water jets

Input Wire Size and Current Derating Table

† Ratings are dependent on input cable sized for appropriate amperages.

Unlatch the two yellow tabs on the fuse cover to access fuses.
The ATO

®

/ATC

®

Fuse Block of the SafetyHub 100 is used for low-amp circuits.

The total continuous amperage of this block must not exceed 50A.
The AMI

®

/MIDI

®

Fuse Block of the SafteyHub 100 is used for high-amp circuits.

The total continuous amperage of this block must not exceed 240A

AWG Wire Size

Metric Wire Size

Amperage Maximum Operating (combined)

4/0 AWG

120 mm²

280A

2/0 AWG

70 mm²

225A

1 AWG

50 mm²

180A

4 AWG

25 mm²

125A

PN 7725 / PN 7725B

PN 7725 includes a connector plug for the ATO

®

/ATC

®

fuse circuits


The Blue Sea Systems SafetyHub 100 is an ignition-protected fuse block
with an integrated connecting plug. It consolidates 1A

200A fuses, and can

be wired directly to the battery (for unswitched fuse protection) or after the
battery switch (for switched fuse protection).

]

Disconnect all battery connections before beginning the installation.

]

Blue Sea Systems strongly recommends that a competent electrical

professional perform the installation of this product.

GUARANTEE: Blue Sea Systems stands behind its products

for as long as you own them. Find detailed information at

www.bluesea.com/about. For customer service, call 800-222-7617.

Marine Electrical Products

SafetyHub 100 Fuse Block

Blue Sea Systems Inc.

p 360.738-8230

425 Sequoia Drive

f 360.734-4195

Bellingham, WA 98226 USA

[email protected]

www.bluesea.com

980004720 Rev.004

Specifications

WARNING

Amperage Maximum Operating (combined)

(see table below)

Nominal Operating Voltage

12V DC

Minimum Input Cable Size to Meet Ratings

4/0 AWG (120 mm²)

Recommended Ring Terminal

M8 (5/16”)

Stud Size

M8 x 1.25

Stud Torque

15 ft-lb (20.3 N-m)

AMI

®

/MIDI

®

Fuse Block

Amperage Maximum Operating (per block)

240A†

Amperage Maximum Operating (per circuit)

170A†

Fuse Amperages Available

30A–200A

Minimum Cable Size to Meet Ratings

2/0 AWG (70 mm²)

Screw Size

M5 x .8 x 10

Screw Torque

27 in-lb (3.0 N-m)

ATO

®

/ATC

®

Fuse Block

Amperage Maximum Operating (per block)

50A†

Amperage Maximum Operating (per circuit)

20A†

Fuse Amperages Available

1A–20A

Regulatory

E

marked

Meets ISO 8846 ignition protection and SAE J1171 external ignition protection requirements.

IP66—protected against powerful water jets

Input Wire Size and Current Derating Table

† Ratings are dependent on input cable sized for appropriate amperages.

Unlatch the two yellow tabs on the fuse cover to access fuses.
The ATO

®

/ATC

®

Fuse Block of the SafetyHub 100 is used for low-amp circuits.

The total continuous amperage of this block must not exceed 50A.
The AMI

®

/MIDI

®

Fuse Block of the SafteyHub 100 is used for high-amp circuits.

The total continuous amperage of this block must not exceed 240A

AWG Wire Size

Metric Wire Size

Amperage Maximum Operating (combined)

4/0 AWG

120 mm²

280A

2/0 AWG

70 mm²

225A

1 AWG

50 mm²

180A

4 AWG

25 mm²

125A

Advertising