Installation instructions, Continued) – Blue Sea Systems 7727 SafetyHub 250 Fuse Block and Solenoid with Manual Control User Manual

Page 2

Advertising
background image

Mounting

Install the SafetyHub in a readily accessible location as close as possible to the

battery.

Mount in a dry and protected location. Avoid mounting directly above

vented lead acid batteries so that the SafetyHub is not exposed to corrosive

gasses from the batteries.
Where possible, mount the SafetyHub in a vertical orientation.

(see illustration 1.1 below)
For help selecting the appropriate wire size and circuit protection rating,

go to

www.circuitwizard.bluesea.com

High Current Input / Remote Battery Switch Connection

Connect the positive battery terminal to the input stud on the SafetyHub.

Torque the connection to 15 ft-lb.

High-Amperage Switched Fuse Circuit Connections

To connect high amperage loads such as an engine starting circuit, distribution

panel, or windlass, use the numbered high amperage studs.
CAUTION Do not switch the Remote Control Switch to OFF while

the engine is running!

Unswitched Fuse Circuit Connections

The fuse connections labeled with letters are designed to be used for circuits

that are always on. PN 7727 includes a wire harness to connect to the

ATO

®

/ATC

®

fuse connector plug receiver.

Control Circuit Connections

(wires contained in the wire harness)

NOTE: The SafetyHub is designed to be controlled by the Remote Control

Switch. Use minimum 18 AWG (1.5mm²) wire for the control circuit.

Remote Control Switch Dimensions

Installation Instructions

1.965"

49.91mm

1.010"

25.65mm

.595"

15.10mm

1.125"

28.58mm

TEST CUT

HOLE IN

ACTUAL

CENTER

1.450"

36.83mm

0.830"

21.08mm

Connector Pin

Wire Insulation Color

Circuit Function

1

Black

External negative

2

N/A

No connection

3

Yellow

LED controlled negative

4

Red

Switch power source

5

Orange

Control signal

6

N/A

No connection

Installation Instructions

(continued)

SWITCHED CIRCUITS

24-HOUR (NON-SWITCHED) CIRCUITS

MOUNTING

HOLES X2

A
B
C
D

1

2

3

PIN OUT Table

Note: Wires used
for engine starting
do not require circuit
protection. If you
choose not to fuse the
engine starting circuit,
use the PN 7732
Engine Circuit Link Bus
(included) instead of a
MIDI

®

/AMI

®

fuse. Do

not use this link for
any other purpose.

Illustration 1.2 - System Diagram

Illustration 1.1 - Mounting Orientation

Mount the SafetyHub 250 vertically as shown in

illustration, and in a dry and protected location.

Engine Link Bus