Refrigerator operation set point programming – Carter-Hoffmann CAA144 User Manual

Page 8

Advertising
background image

REFRIGERATOR OPERATION

SET POINT PROGRAMMING

To enter programming, press the SET key once and “SET” will be
displayed.

1. Press the SET key again and the current temperature set point will be

displayed.

2. Use the UP and DOWN arrow keys to adjust the set point
3. Press the SET key to save the new set point

To exit programming, press the SET and DOWN arrow at the same
time.

TEMPERATURE

CONTINUOUS COLD CYCLE

Press the DOWN key for 8 seconds to activate or deactivate a continuous
cold cycle. (“CON” will flash upon starting the cycle; “COF” will flash upon
completion of cold cycle)

Set Key

Up and
Down
Arrow
Keys

Digital
Display

1. Plug the refrigerator module into a proven power source. The white

indicator lamp and the fan will operate continuously whenever the
heater is plugged in.

2. Be sure the cabinet door(s) are fully closed during the pre-heat time.

3. Set cabinet to desired temperature (see Programming Instructions

below).

4. Allow cabinet to cool to 40°F or lower. This should take approximately

30 minutes.

5. Food serving temperature will vary with the mass, type and quantity

of food being held.

6. During loading, the cabinet temperature will rise. Close the door and

wait 10-15 minutes for the cabinet to recover air temperature before
disconnecting from the power source.

7. Be sure to remove the plug from the outlet and wind the cord on the

cord bracket or push handle before moving the cart. Move the cart to
the service area as quickly as possible.

8. Upon reaching the service area, reconnect the refrigerator module to

power source as quickly as possible. Wait 10-15 minutes (check the
thermometer to see if the temperature is are the desired level). If not
adjust the thermostat as required.

9. When removing product from the cart, start at the bottom and work to

the top position. This eliminates spillage on to lower items.

DEFROST

The refrigeration module will automatically enter the defrost cycle at
scheduled intervals. However, the controller is equipped with a manual
defrost override, if needed. Press the DEFROST key for 8 seconds to
activate or deactivate the defrost cycle.

Defrost
Key

NORMAL OPERATION

In normal operation, the probe temperature will be displayed. The display
blinks when waiting for a parameter to be saved or when there is an error
saving a parameter to memory.

8