37 DIGITAL VIDEO RECORDER

6.2. Alarm Setup

ITEM

ADJUSTMENT

RECORD TIME

y

Determines the duration of recording after the alarm signal has been

activated. [10SEC ~ 300SEC]

RECORD CAMERA

y ALL:

Start to record All Alarm “ON” channel if there is any Alarm signal is

triggered.

y

1:1: Start to record the channel, which Alarm is triggered.

ALARM BUZZER

y

ON: The buzzer Sounds if an alarm is triggered. The buzzer will sound for

the duration of the RECORD TIME. This buzzer related with Alarm

Out. Please configure Alarm Out “ON” for Alarm buzzer.

yOFF:

Disables the ALARM BUZZER function.

ALARM OUT1

y

Configure which relay will be triggered when an alarm is activated per

camera. Select from four available options:

Video Loss, Motion, Alarm ALL, Each Alarm, System.

y

Press [Cancel] button to stop Alarm Out.

It will be cleared by an order: Alarm>Motion> Video Loss

6.

Save changes

and exit the menu, press [ENTER] button.

7.

Press [REC] button after setting RECORD ENABLE. Then, the red REC LED lights on

the front panel and recording starts.

<Note>

If “System” is selected, the relay will be triggered when System

has problems such as HDD FAIL, Power loss etc.

<Note>

Press [-] button to stop the buzzer immediately. Stopping the

buzzer does not stop the alarm recording.