8

Installation

Operation Indicator Lights

Green indicator lights inside the HRU control cabinet
indicate the operation state of the valves during the
set-up procedures. Refer to the set-up procedures on the
previous two pages to set the pressure reducing valves.

In addition, the green lights will indicate the operation of the
booster valves during normal operation. Refer to

the simplified logic diagram below which shows the
interaction of the timers, thermistor reader (temperature
control module) and the booster solenoid valves.

Exhaust Blowers

The HRU Exhaust Blowers operate when the dishwasher
is running.
Exhaust Blower 1: runs whenever the dishwasher pumps
and the final rinse are running.
Exhaust Blower 2: runs when only the final rinse is running.

FINAL

REHEAT

FILL

30 Sec.Timer

15 Sec.Timer

Green Indicator Lights

Thermistor

Reader

Indicator lights inside the control cabinet

indicate the operation of the valves.

Exhaust Blower

Fan 1 (Wire 11B)

Exhaust Blower

Fan 2 (Wire 17B)

Exhaust Blowers as viewed from the front of the dishwasher.

(Left-to-Right Dishwasher Operation Shown)

15 Second Timer (T1)

15 Seconds

Elapsed

Temperature

Less than

110˚F

Temperature
Greater than

110˚F

30 Second Timer (T2)

Cold Water/Final Rinse Valve

Thermistor Reader (TS)

The 15 second timer runs, then the 30 second timer runs in a alternating time cycle

Booster Temperature Thermistor Input

Controls the operation of the T1R

relay. The T1R relay powers the

COLD water valve depending

on the temperature input to

the Thermistor Reader.

The thermistor reader constantly

monitors the temperature of the

booster tank. It controls the

power to the timers through the

contacts of the T1R and T2R

relays. The operation of the

valves is dependent on the

temperature inputs to TS.

Controls the operation of the T2R

relay. The T2R relay powers the

HOT water valve depending

on the temperature input to

the Thermistor Reader.

Hot Water/Reheat Valve

Simplified HRU Cold and Hot Water Switching Logic Diagram

NOTE:

A detailed Logic Diagram is included at the

end of this manual