Limited warranty, Preinstallation information, System installation instructions – Clarus Environmental Centrifugal STEP Systems User Manual

Page 2

Advertising
background image

2

© Copyright 2014. All rights reserved.

Limited Warranty

Lifetime Warranty: Every Clarus Environmental filter is guaranteed to be free from defects in materials and workmanship for the lifetime of the homeowner/purchaser. Free repair

or replacement, excluding labor, will be made on return of the filter prepaid to the factory. This warranty is limited to product proven to be free from abuse or improper installation.

Manufacturer warrants, to the purchaser and subsequent owner during the warranty

period, every new product to be free from defects in material and workmanship under

normal use and service, when properly used and maintained, for a period of one year

from date of purchase by the end user, or 18 months from date of original manufacture

of the product, whichever comes first. Parts that fail within the warranty period, one

year from date of purchase by the end user, or 18 months from the date of original

manufacture of the product, whichever comes first, that inspections determine to be

defective in material or workmanship, will be repaired, replaced or remanufactured at

manufacturer's option, provided however, that by so doing we will not be obligated to

replace an entire assembly, the entire mechanism or the complete unit. No allowance

will be made for shipping charges, damages, labor or other charges that may occur

due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any material or

product that has been disassembled without prior approval of manufacturer, subjected

to misuse, misapplication, neglect, alteration, accident or act of God; that has not

been installed, operated or maintained in accordance with manufacturer's installation

instructions; that has been exposed to outside substances including but not limited to

the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives

(oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels

or feminine sanitary products, etc. in all pumping applications. The warranty set out in

Preinstallation Information

7.

Make sure the pump electrical supply circuit is

equipped with fuses or circuit breakers of proper capacity. A sepa-

rate branch circuit is recommended, and sized according to the

“National Electrical Code” for the current shown on the pump

nameplate.

8.

CAUTION

The installation of pumps using auxiliary variable level

float switches is the responsibility of the installing party and care should

be taken that the tethered float switch will not hang up on the pump ap-

paratus or pit peculiarities and is secured so that the pump will shut off.

9.

Water hammer creates momentary high pressure surges.

These surges can cause severe damage to check valves and the piping

system. Consideration for water hammer must be included in the pip-

ing system design. Reference ASPE Data Book, Chapter 2.33. Some

systems may require external spring or lever weighted check valves or

other engineered solutions.

10.

In cold climates the discharge pipe may be subject to

freezing. If the riser on the septic tank is above the frost line, it will be

necessary to protect the system from freeze up. The discharge pipe can

be insulated or the check valve can be removed. If the check valve is

removed, the “on-off” cycle must be adjusted for any back-flow from the

discharge line.

CAUTION

CAUTION

1. Inspect your unit. Occasionally, products are damaged during shipment.

If the unit is damaged, contact your dealer before using.

2. Carefully read the literature provided to familiarize yourself with specific

details regarding installation and use. These materials should be retained

for future reference.

3.

Do not lift, carry, or hang pump by the electrical

cables. Damage to the electrical cables can cause shock, burns or

death.

4.

For your protection, make certain the pump

ground wire is properly connected to the ground wire with the

incoming power line. Test for ground at the junction box using

an Underwriters Laboratory listed circuit analyzer which will indicate if the

power, neutral and ground wires are correctly connected. If in doubt, call a

qualified licensed electrician.

5.

Make certain that the receptacle is within

the reach of the pump’s power supply cord. DO NOT USE AN

EXTENSION CORD. Extension cords that are too long or too light

do not deliver sufficient voltage to the pump motor. But, more important, they

could present a safety hazard if the insulation were to become damaged

or the connection end were to get wet.

6.

CAUTION

Check to be sure your power source is capable of handling

the voltage requirements of the motor, as indicated on the pump nameplate.

the paragraph above is in lieu of all other warranties expressed or implied; and we do

not authorize any representative or other person to assume for us any other liability in

connection with our products.

Contact manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,

Attention: Customer Service Department to obtain any needed repair or replacement

of part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED

OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A

PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO

THE DURATION OF THE EXPRESSED WARRANTY

Some states do not allow limitations on the duration of an implied warranty, so

the above limitation may not apply to you. Some states do not allow the exclusion or

limitation of incidental or consequential damages, so the above limitation or exclusion

may not apply to you.

This warranty gives you specific legal rights and you may also have other rights

which vary from state to state.

System Installation Instructions

1. Clarus Environmental Centrifugal STEP Systems are designed for

installation in septic tanks through the riser on the discharge end

of the tank. See Fig. 1. If a complete system has been purchased,

all the components will be included except external pipe, fittings,

and riser. Check your Local Code for alarm requirements.

2. All installations must comply with all applicable electrical and

plumbing codes, including, but not limited to, National Electrical

Code, local, regional, and/or state plumbing codes, etc.

3. If the Clarus Environmental Centrifugal STEP System is being

retrofitted into an existing septic system, it will be necessary

to pump and clean out the septic tank before installing. Before

pumping, measure down to the liquid level in the septic tank (not

the scum layer) from the septic tank lid and record. The septic

tank lid becomes the reference point for measuring to correctly

install your system. Take the proper measurements before attempting

to install the new filtered pump system.

4. The outlet pipe is typically 3” below the inlet on a conventional gravity

system. Check the dimensions from the top of septic tank to the

bottom of the inlet and outlet pipe. Each individual system varies

therefore do not assume your system is 3”.

5. An 18” hole is required in the top of the septic tank to install the STEP

system. If the hole in your septic tank is less than 18”, provisions

must be made to open the hole up to 18”. (You may have to change

the lid of the septic tank.)

6. If your system is not equipped with a riser, install a new Clarus

Environmental 24” or 30” diameter riser. Follow the installation

instructions provided with the riser.