Application
Use this filter to screen effluent under pressure. The base screen will

remove particles greater than 1/16" in diameter. An additional filter

sock will screen to either 100 or 600 microns. Applications include

LPP, sand filters, pressure dosed wetlands, drip distribution, and most

pressure applications.

Installation
Determine the discharge pipe length needed from pump to filter. Install

a 2" PVC discharge pipe for the 5000-0001 or a 3" PVC discharge pipe

for the 5000-0008. Note: Pumps with a smaller discharge size may be

adapted to fit. Glue the filter to the end of the discharge pipe. Glue a

6” long PVC pipe to a PVC union ball valve and glue this assembly to

the discharge of the filter. Plumb the discharge into the union and glue.

NOTE: Use PVC primer and solvent on all glue joints.

Service
The Clarus Environmental Pressure Effluent Filter requires periodic

service. The optional Service Alarm Switch will indicate when service

is needed. Excessive pump run times or high water may also indicate

a clogged filter. At a minimum, service the filter each time the septic

tank and/or pump chamber is serviced. Check with your local health

department for pumping recommendations.

To service the filter screen, disconnect power to the pump and unscrew

the 4" lid. Pull the filter screen from the housing and wash it out thoroughly

in an appropriate location with proper protection. Reinsert the cleaned

filter screen, replace the 4" lid and restore power to the pump. For

service providers, a spare screen will allow for a faster service visit,

since the dirty filter can simply be replaced and cleaned later at the

service provider’s convenience.

If the system is equipped with our Service Alarm Switch, the filter screen

does not need service until the Service Alarm Switch activates a light

or audio alarm. Service is still recommended each time the septic tank

and/or pump chamber is serviced.

Sock Installation
To install the sock in a standard filter screen, remove the

1/16" diameter SS wire handle by straightening out the 90° bend in

the wire handle with pliers and removing it from the filter screen. The

sock is installed inside of the filter screen.

At this time, the sock can be placed inside the canister screen and

wrapped around the seating surfaces on the top and bottom. This will

secure the sock in the filter. The sock is a 100 micron thermal nylon

or 600 micron seamless knitted polyester with 100 psi burst strength.

The sock is several inches longer than the filter screen so as to allow

the sock to be pulled around the filter screen flanges and secured as

shown below.

LID W/SEAL

FILTER HOUSING

FILTER SCREEN

OPTIONAL SOCK

INSTALLATION

SK2208A

Pressure Effluent Filter

SECTION: C2.30.130

CL0050

1011

Supersedes

New

3649 Cane Run Road . Louisville, KY 40211-1961

877-244-9340 . Fax: 877-414-4316

www.clarusenvironmental.com

®

®

OWNER'S MANUAL

Advertising