The Fusion

®

is simple in design, yet advanced in its wastewater

treatment ability. The design has been refined over many years

of intense research and development in an effort to perfect

this superior treatment system. Fusion

®

systems are 90% -

95% efficient at treating wastewater. This is nearly twice as

effective as a traditional septic tank, which is approximately

50% efficient. This high degree of treatment helps to protect

both your personal property and the environment.

The Fusion

®

utilizes a combination of anaerobic (without

oxygen) and aerobic (with oxygen) biological processes to treat

wastewater. As wastewater enters the Fusion

®

, it is broken

down and becomes food for biological organisms operating

within the unit. The first chamber serves to separate grease

and large solids from the liquid. In the second chamber, plastic

media with large surface areas are used to increase contact

between water and beneficial bacteria to optimize treatment. A

small linear air blower is used to move air (oxygen) into the third

chamber for the aerobic process. The final effluent leaving the

system will have been treated to secondary quality effluent and

will average *9 mg/L CBOD5 and 9mg/L TSS.

* Based on NSF Standard 40 testing.

HOW A FUSION

®

SERIES TREATMENT SYSTEM WORKS

Anaerobic Chamber -

Organisms adhere to fixed film

media and digest waste

Recirculation Line

Storage

Chamber

Inlet Pipe

4” PVC

SCH 40

(DN 100)

Tank -

Compression

Molded Fiber

Reinforced Plastic

Sedimentation

Chamber -

Separates bulk solid

and grease waste

Outlet Pipe

4” PVC

SCH 40

Aeration Chamber

Floating/Circulating

Filter Media -

“Fluidized Bed”

Invigorates aerobic bacteria

Sludge Return Line

Figure 1 - The following diagram will help you to better understand the process:

Figure 2 - Schematic diagram of the Fusion

®

Treatment System

(DN 100)