Clarus Environmental Spider Valve User Manual

Installation instructions, Installation steps, Spider valve

Advertising
background image

Notice to iNstaller: instructions must remain with installation.

© Copyright 2013. All rights reserved.

FIGURE 1

SK2322

ALL WORK IN ACCORDANCE

WITH NEC AND ANY OTHER

STATE OR LOCAL CODES

SEPTIC TANK

STEP SYSTEM

24 OR 30 INCH

ACCESS RISER & LID

FILTERED

ALARM

WIRING

CONDUIT

TO OTHER TRENCHES

EFFLUENT

VALVE

SPIDER

CLARUS

FIGURE 1

TYPICAL GRAVITY

TRENCH

MANIFOLD

* The Distal Pressure selected will need to be added to the friction head and static head for the TDH.

Distal Pressure

Flow (GPM) per Orifice

Feet*

psi

5/32"

3/16"

7/32"

1/4"

9/32"

5/16"

11/32"

3/8"

3

1.30

0.52

0.75

1.03

1.34

1.70

2.09

2.53

3.01

4

1.73

0.60

0.87

1.18

1.55

1.96

2.42

2.92

3.48

5

2.16

0.68

0.97

1.32

1.73

2.19

2.70

3.27

3.89

6

2.60

0.74

1.07

1.45

1.89

2.40

2.96

3.58

4.26

SK2323

Installation Steps

1. Spider Valve

®

assembly must be

installed at the high point of the system

such that the effluent will gravity drain

from the valve to the disposal trenches.

Consult site plan and Figure 1.

2. At least 3' of distal pressure should be

maintained on the manifold to ensure

proper effluent splitting.

FIGURE 2

DETAIL "A"

1/2" FLEX PIPE

WITH GRAVEL

TOP OF MANIFOLD

FILL TO NEAR

DETAIL "A"

TRENCH

TO DISTRIBUTION

BASE

2" GRAVEL

2" MANIFOLD

PLACE WASHER INSIDE

UNIONS DURING FIELD ASSEMBLY

1/2 X 1 1/4

RED BUSHING

NOTE: For sizing help please consult Clarus

Environmental at 1-800-928-7867 or use the Spider

Valve

®

Orifice Sizing Tool to help design your onsite

system at www.clarusenvironmental.com

Spider Valve

®

sectioN: c4.00.013

CL0078

0813

Supersedes

0112

3649 Cane Run Road Louisville, KY 40211-1961

800-928-7867 Fax: 502-774-3624