clarUs eNViroNMeNtal VariaBle leVel PUMP sWitcH

REFER TO OTHER SIDE FOR INSTRUCTIONS FOR ALL APPLICATIONS.

FIGURE 5

FIGURE 7

FIGURE 9

FIGURE 6

A) Remove (cut) Piggyback

Plug from Variable Level

Pump switch. Remove

approx. 3½” of cord

jacket and 1” insulation

from wires.

b) Wire switch into circuit as

shown.

C) Return to instructions.

D) Installation must be

in agreement with the

National Electrical Code

and all local codes.

FIGURE 8

(b)

DIsTANCE

FROM MOUNTING

CLAMP TO FLOAT

IN INCHEs

NOTE: Measurements as shown are approximate.

Exact measurements to be determined for each

individual installation.

(A)

PUMPING RANGE

IN INCHES

iNstallatioN iNstrUctioNs

1. Decide the desired pumping range for your installation instruction. (See Fig.5 and Figure 10.) (B) is the

distance between the mounting point of attachment and the float. The distance (B), determines (A), the

desired pumping range.

2. At Distance (B), determined from Figure 10) place the cord into the clamp as shown in Fig. 6.

3. Position the float to the desired “OFF” level and secure the clamp to the discharge pipe as shown in Fig.6.

See Fig. 5 noting water line. NOTE: Do not install cord under hose clamp.

4. Tighten hose clamp using a screw driver. NOTE: Do not over tighten. Over tightening may result in

damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp

band during operation.

Notice: Do not adjust “off’’ level below discharge on pump.

5. Insert the piggyback plug from the switch into a standard grounded outlet of proper voltage. For automatic

operation, plug the pump directly into the piggyback plug. (See Fig. 7.) Pump can be manually operated

by bypassing the piggyback plug.

Notice: For installation utilizing watertight junction box or similar connections, see Figure 8.

Notice: For installation as a control switch for magnetic starter, see Figure 9.

6. Tape or clamp both piggyback switch and pump cords to the discharge pipe, clear of float operation. (See

Fig. 5.) Excess cord should be coiled and fastened outside the basin.

7. Clean basin free of debris after installation.

8. Check your installation. Fill basin with water and allow pump to cycle to insure proper range and operation.

Clarus Environmental Variable Level Pump Switches are designed for use with the appropriate voltage and horsepower, nonautomatic, single phase, Clarus

Environmental pumps. Maximum liquid temperature must not exceed 120°F for 10-0748.

Clarus Environmental Variable Level Pump Switches can be used as a control switch for a magnetic or combination starter. Maximum temperature must not exceed

140° F. See figure 9.

Single Variable Level Pump Switches are recommended for use in 18” minimum diameter pits or basins.

Note: Consult Clarus Environmental for controlling units over 1½ HP with a variable level pump switch.

sk1301D

FIGURE 10

3.5 INCH

TETHER LENGTH

FOR DOUBLE

FLOAT

3.5 INCH

MINIMUM

TETHER LENGTH

FOR PUMP

SWITCH

25

40

35

30

25

10

5

15

20

0

20

15

5

10

P/N 10-0033

P/N 10-0034

P/N 10-0055

P/N 10-0032

P/N 10-0035

P/N 10-0706

P/N 10-0559

P/N 10-0705

P/N 10-0063

P/N 10-0748

sk1299

PUMP PLUG

SWITCH PLUG

AUTOMATIC

OPERATION

MANUAL

OPERATION

sk308A

VARIABLE

LEVEL

PUMP

SWITCHES

sk378A

VARIABLE

LEVEL

PUMP SWITCH

sk306A

A

B

"ON"

LEVEL

"OFF"

LEVEL

CORDS SECURED TO

DISCHARGE PIPE

sk305b

All Clarus Environmental products must be installed and maintained in accordance with all applicable codes.

Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.

10-0055 - 115V/Max. ½ HP 13A 10 cord*

10-0032 - 115V/Max. 1 HP 15A 15 cord*

10-0033 - 230V/Max. 2 HP 15A 15 cord*

10-0034 - 115V/Max. ½ HP 13A 15cord*

10-0035 - 230V/Max. 1 HP 13A 15 cord*

*for EFFLUENT, SEWAGE and DEWATERING (120°F Maximum Liquid Temperature)

10-0063 - 115V/Max. ½ HP 13A 20’ cord*

10-0559 - 230V/Max. 2 HP 15A 20’ cord*

10-0705 - 115V/Max. ¾ HP 15A 20’ cord*

10-0706 - 230V/Max. 1 HP 13A 20’ cord*

10-0748 - 230V/Max. 3 HP 20A 25’ cord* (No Plug)