STEP 8

Final Adjustment

8.1) Check the level on the diverter. If adjustment is not needed, proceed to the next step. If adjustment is needed,

reference the Maintenance Instructions (below) for proper adjustment and leveling of the diverter.

Your new Clarus Environmental Splitter System is now in service.

Maintenance

1)

Remove cap on riser.

2)

Check the level on the diverter with flashlight. If the level

does not need adjustment, then maintenance is not required

at this time. If level is not centered between the lines, then

proceed to the next step.

3)

Loosen the thumb screw (two full turns max) until the diverter

can be adjusted. The thumb screw can be adjusted by hand

or by using a ¾" pipe ( not supplied) with a slot as shown in

Figure A.1.

4)

Using the ¾" pipe, or by hand, tap at point “A” or “B” on the

bottom surface of the diverter until the diverter is level. See

Step 6 on page 3, Figure 6.1.

5)

Once the diverter is leveled, tighten the thumb screw until the

diverter is stationary. DO NOT OVERTIGHTEN THE THUMB

SCREW. Check bubble level with flashlight. If diverter

becomes unlevel during tightening, repeat steps 3, 4 and 5.

6)

Replace cap on riser.

The splitter system should be checked annually in conjunction with your yearly septic system inspection.

THUMB SCREW

3/16" X 3/16"

SLOT

3/4" PIPE

AS NEEDED

Figure A.1

SK1953

All Clarus Environmental products must be installed and maintained in accordance with all applicable codes.

Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.

Replacement Parts List for Model 173-0001 Splitter System

SK1954

REF.#

DESCRIPTION

QTY.

PART

173-0001

1

Hardware Pack

1

013236

2

Cover

1

013043

3

Slotted Pipe Nipple

1

013241

4

Diverter

1

012925

5

Basin

1

013044

8

Thumb Screw, Plastic 3/8"-16

1

013239

10

Washer, SS-1" O.D.

1

006413

U.S. Patent Nos.

6,152,650 and 6,112,766

(BLANK COVER)

(3 SEALS NOT SHOWN)

(2 COVERS NOT SHOWN)

(RESTRICTOR COVER)
(2 COVERS NOT SHOWN)

4

14

13

10
11

12

5

3

9

8

6

2

1

HARDWARE PACK P/N 013236

REF.#

P/N

DESCRIPTION

QTY.

6

014515

Screw, SS#12 x 3/4" Phillips

12

9

013238

Pipe Seal, Tuf-Tite-SDR 35

6

11

013237

Bubble Level, 3/8" x 1 3/8" LG

1

12

013240

Slot Cover

3

13

011644

Screw, SS #10-16 x ½" Phillips

2

14

013753

Cover, Slot Diverter