Failure to properly remove the XR hubnut
from the balancer shaft may result in its
premature wear, damage to its threaded
jaw/internal diameter and/or even the
balancer shaft.

To prevent premature wear and to extend its ser-

vice life, use the following techniques when remov-
ing the XR hubnut.

Releasing XR Hubnut

1. First, manually unscrew the XR hubnut one full

turn, figure 1.

Figure 1 - Unscrew One Full Turn

2. Next, press the release to retract the threaded

jaw inside the XR hubnut, figure 2.

Figure 2 - Release Threaded Jaw

Sliding XR Hubnut

3. Now, hold the release and slide the XR hubnut

off the balancer shaft.

Important: Before removing or installing the XR

hubnut, be sure the threaded jaw is fully disengaged
by pressing and holding hubnut release, figure 3.

Figure 3 - Threaded Jaw Disengaged