COATS Kit 8111177 Three Phase to Single Phase Conversion User Manual

COATS Equipment

Advertising
background image

8111179 01 07/02

© COPYRIGHT 2002 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.

Three Phase to Single Phase Conversion

Kit #8111177

for 950/1050 Wheel Balancer

COATS, Inc. • Hennessy Industries • 1601 J.P. Hennessy Drive, LaVergne, TN 37086-3565

(800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com

1. Unplug the balancer from the power source.

2. Remove the weight tray shield from the balancer.

3. Remove the two (2) screws that retain the plas-

tic side pocket on the left side of the balancer.

4. Attach the capacitor and bracket assembly to the

left side of the balancer.

5. Unplug the three phase jumper from the motor

control board slot marked “capacitor”.

6. Tape the three phase jumper to the capacitor

assembly for use in converting the unit back to three
phase.

7. Insert the connector on the capacitor wires into

the slot used previously for the three phase jumper
marked “capacitor”.

8. Change the plug on the power cord and connect

the wires to the single phase plug according to the
diagram in figure 1. The white wire is not used for sin-
gle phase and should be folded back and taped
securely to the other wires.

9. The white wire in the power cord is not used for

single phase and should be unplugged from the motor
control board, folded back, and taped securely to the
other wires.

10. Install the weight tray shield and weight tray.

11. Install the plastic side pocket.

12. Clean the area of the hood above the “wheel

size limit” decal p/n 8111883 and apply the “duty
cycle” decal p/n 8113462 to that area.

Figure 1 - Single-Phase Wiring Diagram

Single-Phase

A – Red

B – Black

Green/

Ground

Advertising