COATS Kit 8113932 16 Bit PCB & Metal Arm User Manual

Instructions

Advertising
background image

8113933 02 4/05

© COPYRIGHT 2004 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.

16 Bit PCB & Metal Arm Kit #8113932

COATS, Inc. • Hennessy Industries • 1601 J.P. Hennessy Drive, LaVergne, TN 37086-3565

(800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com

Instructions

1. Replace the PCB. Repack the old PCB and return it

to Hennessy Industries.

2. Remove the Plastic Diameter Arm from the dis-

tance rod.

3. Place the large black fender washer (in Kit) under

the existing 6mm screw. Then attach the Metal
Diameter Arm, supplied in the Kit, to the distance rod.

4. Important: It is necessary to perform a NOVRAM

reset on startup.

5. Power up machine and check for function of all

operations. Make any necessary adjustments:

• Ensure that Distance and Diameter Pots are set

between 2500 & 3500 on Machine Self-Test (Green
Screen).

• If Arm Calibrations are required:

Press the

key and select the SERVICE

ADJUSTMENTS option

. At the PASSWORD

prompt enter 1-3-5-7.

Toggle the DISTANCE/DIAMETER ARM TYPE
option to

METAL.

In the following order, select the DISTANCE ARM
CALIBRATION option

, WIDTH SONAR CALI-

BRATION option

, and DIAMETER ARM CALI-

BRATION option

, following the on-screen

instructions for each calibration. Note: At the end of
the Diameter Arm Calibration, hold the NEXT but-
ton down until 281 degrees flashes on-screen; then
return the arm to its home position.

Important: Once the Arm is calibrated, there is lit-
tle need to calibrate it again.

6. To Calibrate with the 4-ounce weight, press the

key, then select SPECIAL FUNCTIONS option

and choose MACHINE SELF-CALIBRATION selec-

tion

. Follow the instructions on-screen.

Important: The dimensions entered must match the

“calibration wheel”. A dimension cannot be zero.

7. If not already done, you may want to enter the

Owner Name and Address for the screen saver. The
OWNER ADDRESS selection is found under the SPE-
CIAL FUNCTIONS menu.

8. The Board is factory set with the following menu

settings:

General Set-up

Runout Unloaded

" = SONAR (radial)

Balancing Set-up

Runout Diagnostic = ON

Runout Limits

Max. True Limit = .050"
Rim Runout Limit = .010"
Correction Runout Limit = .030"

Special Functions

Static Unbalance Displayed = ON
Stop On Top = OFF

6

7

MENU

3

2

1

5

4

MENU

Advertising