COATS Kit 8114105 PCB Assembly Kit User Manual

COATS Equipment

Advertising
background image

8114106 00 10/04

© COPYRIGHT 2004 HENNESSY INDUSTRIES AND COATS ALL RIGHTS RESERVED PRINTED IN U.S.A.

PCB Assembly Kit #8114105

Installation Instructions for Ground Strap and PCB

(950 Racer)

COATS, Inc. • Hennessy Industries • 1601 J.P. Hennessy Drive, LaVergne, TN 37086-3565

(800) 688-6359 • (615) 641-7533 • (615) 641-5104 FAX • www.ammcoats.com

Description

Recent findings have shown that Electro-Static

Discharge (ESD) can cause significant damage to a bal-
ancer. The addition of a ground strap will help to
increase the ESD immunity of the balancer. If your bal-
ancer already has the ground strap, verify that it is
making good contact and is installed correctly.

Parts List

#8114104 - PCB Assembly

#8113073 - Ground Strap

Installation

1. Remove the Touch Panel and Printed Circuit Board

(PCB) assembly from the balancer.

2. Disconnect the wires from the PCB.

3. Connect one end of the Ground Strap to the

Balancer Pod Tube, see figure 1. Wiggle the ground
strap to ensure that a good ground connection is made
with the Balancer Pod Tube.

Note: If PCB is already equipped with a ground strap,

simply reconnect to standoff and ensure other end has
a proper connection.

4. Now connect the other end of the ground strap to

the bottom right standoff that is on the backside of the
Touch Panel underneath the PCB, see figure 2.

5. After installation of the ground strap (see figure 3)

is complete, reconnect the wire harness to the PCB,
and reinstall the Touch Panel/PCB assembly on the bal-
ancer.

6. Run the balancer through a complete calibration

to ensure proper operation.

Fig. 1 - Ground Strap connected to Balancer Pod Tube.

Balancer

Pod Tube

Ground Strap

Fig. 2 - Ground Strap connected to bottom right standoff.

Fig. 3 - Ground Strap installation complete.

Bottom Right

Standoff

Advertising