Warning caution, Maintenance instructions – COATS 1250 Series Balancer User Manual

Page 24

Advertising
background image

18 •

Important: Always read and follow the information box instructions.

3. Bring the tip edge of the arm precisely to the outer

edge of the faceplate and hold it there while pressing

the NEXT key. (If necessary to reach the faceplate

accurately, loosen the calibration wheel temporarily.)

4. With the arm still at the edge of the faceplate,

enter the A dimension shown on the arm rod. Press

the NEXT key.

Figure 22 - While Holding Arm at Faceplate Edge, Enter A

5. Move the arm to its home position and press the

NEXT key.

6. Move the arm to the clip-on weight location on the

rim flange and hold it there while manually entering the

D dimension. Press the NEXT key.

7. While still holding the arm at the clip-on weight

position on the wheel, enter the dimension read off

the arm rod. Press the NEXT key.

8. Return the arm to home position; calibration is

complete.

Important: To redo the Arm Calibration procedure,

press and hold SHIFT and press 0, then press 19 to

bypass the Machine Calibration requirement. Always

use the same wheel assembly that was used during

the machine calibration or else the calibration will not

be correct.

Maintenance Instructions

The balancer requires only minor maintenance to

keep the unit operating properly.

1. Keep the display clean and clear. Use a damp

cloth. Do not use cleaners or solvents which leave oily

or filmy residues behind.

2. Keep the adapters, cones, faceplate, threaded

shaft, pressure cup, and hub nut clean. Grease and dirt

buildup will cause inaccurate balancing and premature

wear. Clean these items at least once a day with a

vaporizing solvent.

3. Clean weight tray and any accessory posts, pegs,

or storage shelves with a vaporizing solvent. Weights

stored in a dirty tray may pick up grease and dirt which

may keep them from securely attaching to the wheel.

Use common sense, this is an electrical
device. Exposing the balancer to water,
either by hose or bucket, or by exposure to
rain or snow, may cause risk of shock or
electrocution to operator or bystanders.
Place, store, and operate the balancer only
in a dry, sheltered location.

Do not hose down with water or bucket
wash the balancer. Extensive damage to the
balancer will result. Sensitive electronic
components, wiring harnesses, and other
devices housed in the balancer are not
intended to be exposed to water.

4. Keep the area around and under the balancer

clear. Remove any tools or other items that are leaning

against the balancer. Remove any items that may

cause the balancer to not sit level. Be particularly cau-

tious of new or used wheel weights on the floor, as

they may cause personal injury due to falls.

5. Use only COATS

®

accessories. Accessories from

other manufacturers may not fit or function properly,

and may damage the balancer.

6. To replace Arm Laser battery, remove cover (fig.

23). Discard old battery. Install a new battery and

replace the cover.

Figure 23 - Replacing Arm Laser Battery

WARNING

CAUTION

Arm Laser

Battery Cover

Advertising