Separator/Lubricator Maintenance
Check oil and water levels regularly, and perform
these maintenance items weekly:

A. Disconnect air supply to machine.

B. Drain water from the separator by unscrewing

the petcock on the bottom of bowl. Allow water
to drain and tighten petcock securely by hand.

C. Add oil to the lubricator if the fluid level is more

than 1/4" from the top of the gauge. Remove the
filler plug on top of the lubricator and add SAE
10W non-detergent oil or an air tool oil to bring
the level up to 1/4" from the top of the gauge.
Replace filler plug and clean up any spilled oil.

D. Adjust the oil flow by pulling the adjustment

knob up and turning it to increase or decrease
the flow. Push the knob down to lock. Watch the
formation of oil drops in the see-through oil
chamber. Reconnect the air supply and
continually cycle the bead loosener through full
strokes and count the drips during the cycles.
The delivery of oil to the air line should be about
1 drop per 10 cylinder cycles. Adjust flow as
required.

Mount/Demount Head Cleaning
Clean dirt and debris from the mount/demount tool
(duckhead) roller with small screw driver or pick.

INSTALLATION INSTRUCTIONS

Proper unit installation
is necessary for safe
use and efficient

operation. Proper installation also helps protect
the unit from damage and makes service easier.
Always place safety poster and instructions near
the unit.

Location
Select a location using the drawings below. The
area should provide the operator with enough space
to use the equipment in a safe manner. The area
selected should be well lit, easy to clean and should
be away from oil, grease, brake lathe chips, etc.
Avoid areas where bystanders and customers may
be present.

Workspace Requirements

Air Source
The 5035 requires a 5 CFM air source at 150 PSI.
The safe operating pressure range is between 110
PSI and 175 PSI at the machine.

The unit is furnished with a 1/4" pipe thread male
fitting for easy connection. This connection is
located on the right side of the rear of the machine.
A 1/4" ID hose (or pipe) for connection to the
machine is satisfactory. Sufficient air pressure
assures good performance.

5035 A/E Rim Clamp Tire Changer • 15

76"

66"

66"

Drain

Petcock

Air In

Air Out

Oil Fill