Caution, Setup instructions – COATS 5030 A/E Tire Changer User Manual

Page 23

Advertising
background image

Important: Always read and follow operating instructions.

• 19

Setup Instructions

CAUTION

Proper unit installation is necessary for safe
use and efficient operation. Proper installa-
tion also helps protect the unit from dam-
age and makes service easier. Always place
safety poster and instructions near the unit.

Location

Select a location using the drawings below. The area

should provide the operator with enough space to use

the equipment in a safe manner. The area selected

should be well lit, easy to clean and should be away

from oil, grease, brake lathe chips, etc. Avoid areas

where bystanders and customers may be present.

Workspace Requirements

Air Source

The 5030 requires a 5 CFM air source at 150 PSI. The

operating pressure range for all models is between 110

PSI and 175 PSI at the machine.

The unit is furnished with a 1/4" pipe thread male fit-

ting for easy connection. This connection is located on

the right side of the rear of the machine. A 1/4" ID hose

(or pipe) for connection to the machine is satisfactory.

Sufficient air pressure ensures good performance.

Electrical Source

Electrical models require power as follows:
15 amp, 115V, 60 Hz, 1 PH electrical circuit
Refer to the caution decal that is located by the unit’s

power cord.

Refer to the serial tag located on the lower part of

the machine for specific electrical requirements for

the unit. Have a licensed electrical technician perform

any necessary changes to the power source before

plugging in the unit. The electrical source must have a

solid connection (less than 1 ohm) between ground and

building ground.

Floor Mounting

As Hennessy can not be certain of the environment

and conditions of the locations where the equipment

will be installed, it is recommended that the safety

manager review the shop floor conditions and local

regulatory practices to determine if bolting of the equip-

ment to the shop floor is necessary or advisable.