Troubleshooting Guide

Problem Possible

Causes

Carrier does not exit at destination

• Duct is obstructed
• Duct is not airtight
• Duct length is too long
• Carrier is worn or the wrong size
• Too much tension on blowline
• Too many bends in the conduit

Blowline builds up in duct

• Drag plate is not properly set
• Carrier is worn or the wrong size

Unit does not turn on

• Blown utility fuse—not rated for 12 amperes
• Blown fuse in Power Dart Blower
• Bad electrical connection

Replacement Parts List

Part Description

Part Number

Outlet Fitting

08039302

Plastic Handle

08066700

Power Switch

02289289

7' Power Cord (10 Ga., 3 Con.) (for 120 VAC unit)

00181700

Plug, (125V, 30 Amp Twist) (for 120 VAC unit)

08930103

Fuse, (250V, 15 Amp Type Fast Acting) (for 120 VAC unit)

02259600

7' Power Cord (2.5 mm, 3 Con.) (for 220-240 VAC unit)

00181800

Plug, Elect. (250V, 16 Amp European) (for 220-240 VAC unit)

02279300

Fuse, (250V, 6.3 Amp Type Fast Acting) (for 220-240 VAC unit)

02289292

Label Kit

08065226

NOTE: Each motor has a protective fuse. They are
conveniently located on the front panel’s lower right corner.

1.

Use a straight-slot screwdriver to rotate the fuse holder

1

4

turn counterclockwise.

2.

Pull the fuse holder out and remove the fuse.

3.

Insert a new fuse into the holder.

4.

Push the fuse holder into its receptacle and rotate it

1

4

turn clockwise.

Fuse Replacement Procedure

Air Hose

Seal-Off

Rear Air Outlet

Air Inlet

Power Switches

!WARNING: Forced air creates flying
debris. Always wear personal protective
equipment. Severe personal injury could
result.

!DANGER: Do not remove or modify
the 30 AMP-115 VAC twist plug, or the
16 AMP-230 VAC European plug. Severe
personal injury, death, or property
damage could result.

!DANGER: The Power Dart

®

Blower is an

electrical device. Use proper precautions
during its setup and operation. Failure to
do so could result in severe personal
injury or death.

!WARNING: Ensure no personnel are in
the destination access vault during the
blowing operation. Severe personal
injury could result.

Blowline

Line Carrier

Access Hole

Drag Plate

Advertising