The Universal Seal-Off Control Valve Body is used with the Innerduct Seal-Off, and the Single or Double Conduit

Seal-Off. Use the interchangeable heads for the style and size you need. The Control Valve Body comes equipped

with an air flow valve and a universal hose coupling for attachment to most compressors. A 3/16in rope adapter

is included.

Single or Double Seal-Off Heads

1. Connect the

Seal-Off Head to the Universal Seal-Off Control Valve using the Quick Connect Couplers.

2. Insert the

rope through the rope adapter that extends from the top of the Universal Seal-Off Control Valve and

tie the line to the projectile or carrier.

3. Place the projectile or

carrier into the duct and then insert the Conduit Seal-Off in the duct until the rubber seal

is inside the

duct.

4. Turn the

wingnut handle clockwise until it is tight. Ensure the Conduit Seal-Off is straight in the duct and the

rope adapter remains on top.

5. Close the

air flow valve by turning it until it is perpendicular to the air hose coupling.

6. Attach the

compressor air hose to the air hose coupling on the end of the Universal Seal-Off Control Valve.

Insert hose safety clip.

!WARNING: Always use safety clips on pneumatic hose couplings or severe personal injury could result.

Ensure the air pressure is 15psi or less.

NOTE: The optional Air Gauge Adapter (08032175) can be installed between the Seal-Off Head and the

Universal Seal-Off Control Valve to ensure air pressure does not exceed 15psi.

7. Slowly open the

air flow control valve on the Universal Seal-Off Control Valve until the rope begins to feed

through the

duct. This valve can also regulate the projectile or carrier speed.

Innerduct Seal-Off Heads

Connect the

Seal-Off Head to the Universal Seal-Off Control Valve using the Quick Connect Couplers.

1. Insert the

rope through the rope adapter that extends from the top of the Universal Seal-Off Control Valve and

tie the line to the projectile or

carrier.

2. Place the projectile or

carrier into the duct and then insert the Innerduct Seal-Off in the duct.

3. Twist the

Innerduct Seal-Off clockwise until it seats tightly inside the duct. Ensure the rope adapter remains

on top.

4. Close the

air flow valve by turning it until it is perpendicular to the air hose coupling.

5. Attach the

compressor air hose to the air hose coupling on the end of the Universal Seal-Off Control Valve.

Insert hose safety clip.

!WARNING: Always use safety clips on pneumatic hose couplings or severe personal injury could result.

Ensure the air pressure is 15psi or less.

Note: The optional Air Gauge Adapter (08032175) can be installed between the Seal-Off Head and the

Universal Seal-Off Control Valve to ensure air pressure does not exceed 15psi.

6. Slowly open the

air flow control valve on the Universal Seal-Off Control Valve until the rope begins to feed

through the

duct. This valve can also regulate the projectile or carrier speed.

Removal Procedure

Conduit Seal-Off & Double Seal-Off:

1. Close the

air flow valve at the air compressor. Wait for the pressure in the conduit and air hose to subside.

2. Disconnect the

compressed air hose.

3. Loosen the

Conduit Seal-Off or Double Seal-Off by turning the wing nut handle counterclockwise and pull the

Seal-Off out of the duct.

Innerduct Seal-Off:

1. Close the

air flow valve at the air compressor. Wait for the pressure in the conduit and air hose to subside.

2. Disconnect the

compressed air hose.

3. Loosen the

Innerduct Seal-Off by twisting it counterclockwise and pull the Innerduct Seal-Off out of the duct.

Seal-Off Applications

!WARNING: Read and understand

all procedure and safety instructions

before using any Condux Innerduct

Seal-Off, Conduit Seal-Off & Double

Seal-Off. Failure to do so may result

in personal injury or property

damage. Save this user’s guide for

future reference.

!WARNING: Do not exceed 15 psi

of air pressure. Do not stand

directly behind the Seal-Off.

Serious personal injury could

result.

!CAUTION: Wear personal

protective equipment: hard hat,

safety glasses, safety shoes, and

leather work gloves.

!WARNING: Keep the compressed

air hose-couplings clean of debris.

Compressed air blows surrounding

debris during the installation and

removal of the air line. Serious

personal injury could result.

!CAUTION: Beware of sharp threads

on the seal-off head - wear leather

work gloves when handling or

personal injury could result.

Operating Procedure

!ADVERTENCIA: Favor de leer y

comprender todas las instrucciones

de operación y seguridad antes de

usar el Condux Innerduct Seal-Off,

Conduit Seal-Off & Double Seal-Off.

Si Ud. no comprende las instruccio-

nes favor de consultarle a su jefe.

ADVERTENCIA

Instrucciones

de Operación

Universal

Seal-Off

Control Valve

Innerduct Seal-Off

Rope Adapter

Rope

Air Hose

Quick Coupler

Carrier

Figure 2 - Innerduct Seal-Off Application

Figure 1 - Conduit Seal-Off Application Shown W/Optional Air Gauge Adapter

Optional Air

Gauge Adapter

Advertising