CONDUX WINCH LINE BLOWER

22

OBSTRUCTION.

will clear the conduit of light

obstructions. The missile is also
able to maneuver through most

areas where the conduit may be

deformed and flattened. If the

missile is not able to pass through
the conduit, the conduit is fully

plugged or has a major conduit

obstruction.

MISSILE GOES INTO CONDUIT A
DISTANCE BUT WILL NOT EXIT AT

OTHER END DUE TO TOO MUCH

BACK FORCE ON THE MISSILE.

1.

The winch line is exerting too great
of a back force on the missile to

propel the missile and cable any

further. This may be due to too

many bends in the run, the distance
of the conduit run being too great,

or the tension on the winch line

being too large.

SEAL OFF ASSEMBLY SLIPS OUT OF

THE PIPE

1.

Using an adjustable wrench screw

the threaded adapter into the duct

tighter.

2.

Check the threads for wear.