1.

Use the correct size pulling harness for the job (Table 1).

2.

Connect a Condux

808 or 821 Champion Swivel to the pulling

harness’ large

front link.

3.

Connect the pulling harness’

staggered legs to the proper style

pulling eyes, depending upon the pull.

NOTE: Various methods are available to connect the Multiple Pulling
Harness to the pulling eyes. If the pulling eye doesn't have a clevis
head, use either Condux Swing Links or Swivel Connectors. Consult
your Condux catalog, or see your Condux representative for more
information. Other harness combinations available upon request.

Installation Procedure

!WARNING: Read and understand all procedure

and safety instructions before using any Condux®

Multiple Pulling Harness. Failure to do so may

result in personal injury or property damage. Save

this user’s guide for future reference.

!WARNING: Do not use the Multiple Pulling

Harnesses for overhead lifting or any other

purpose. They are for cable and innerduct pulling

only. Severe personal injury or property damage

could result.

!CAUTION: Wear personal protective equipment:

hard hat, safety glasses, safety shoes, and leather

work gloves. Failure to do this could result in

personal injury.

!WARNING: Do not stand directly behind the pull

string. If any component breaks, severe personal

injury or property damage could result.

!WARNING: Do not exceed the load capacity of the

Multiple Pulling Harness or any element in the pull

string. Severe personal injury or property damage

could result.

!ADVERTENCIA: Favor de leer y comprender todas

las instrucciones de operación y seguridad antes

de usar el Condux® Multiple Pulling Harness. Si

Ud. no comprende las instrucciones favor de

consultarle a su jefe.

ADVERTENCIA

Instrucciones

de Operación

Table 1. Multiple Pulling Harness

Figure 1. Multiple Pulling Harness Connection

Pulling Eyes

Staggered Legs

Front Link

808 or 821
Champion Swivel

Part Number

Description

Working Load

Per Leg

Working Load

Combined

Max.

Width

Separation

Between

Legs

Lead Ring

Dia.

A

Leg
Dia.

B

(lbs)

(N)

(lbs)

(N)

(in)

(mm)

(in)

(mm)

(in)

(mm)

(in)

(mm)

08549200

3 Way

1

8

" (3 mm) Cable

550

2,446

1,600

7,117

2.25

57

14

356

.37

10

.12

3

08549230

3 Way

1

4

" (6 mm) Cable

1,400

6,227

2,900

12,899

3.00

76

14

356

.37

10

.25

6

08549325

4 Way

1

4

" (6 mm) Cable

1,400

6,227

4,200

18,682

3.75

95

14

356

.37

10

.25

6

08569910

5 Way

1

4

" (6 mm) Cable

1,400

6,227

4,200

18,682

3.75

95

14

356

.37

10

.25

6

08549333

3 Way

3

8

" (10 mm) Cable

4,800

21,350

9,000

40,032

2.63

67

10

254

.62

16

.37

10

08549329

4 Way

3

8

" (10 mm) Cable

4,800

21,350

9,000

40,032

2.63

67

10

254

.62

16

.37

10

08549331

2 Way

1

2

" (13 mm) Cable

7,000

31,136

10,000

44,480

2.50

64

12

305

.50

13

.50

13

08549332

3 Way

1

2

" (13 mm) Cable

7,000

31,136

15,000

66,720

3.75

95

12

305

.87

22

.50

13

08549340

4 Way

1

2

" (13 mm) Cable

7,000

31,136

15,000

66,720

3.75

95

12

305

.87

22

.50

13

Advertising