Control Company 4261 TOUCH TACHOMETER User Manual

Control Company Measuring instruments

Advertising
background image

OPERATION MANUAL

LCD Display/Indicator

: Low Battery Indicator

RPM: Rotations per minute

M/Min:

Meter per minute

Ft/Min:

Feet per minute

Yd/Min:

Yard per minute

HOLD: Reading hold

FRONT PANEL DESCRIPTION

1. Cone (convex) Adapter

2. Funnel (Concave) Adapter

3. Wheel for linear surface

4. Contact Adapter

5. Unit select key

6. Power on/off & Hold key

7. Battery Cover (rear)

8. Power on/off

9. Front Panel & LCD display

METER PER SECOND (M/SEC)

= Ft./Min x 0.00508

= M/Min / 60

= Yd/Min x 0.01524

MEASURE OPERATION

A. Power ON/OFF

Power on the Tachometer by pressing the Triangle

button (POWER, HOLD) key is pressed. Full display

appears in half second, then turn to a normal mode.

Power off the meter by pressing and hold (POWER,

HOLD) key for 3 seconds.
The meter powers OFF automatically after non-opera-

tion in 20 minutes.
The meter has an unique design with two power keys,

one at the middle of top view, another key is smaller at

the bottom of the meter for easy power on or off when

measuring an object at a downview location. (See point

8 from Front panel description).

B. Data HOLD

This meter automatically holds the last reading on the

LCD after the POWER/HOLD key is released. No extra

key presses are necessary to freeze the displayed

reading.

DISABLE SLEEP MODE

To disable Sleep mode, make sure the meter is off. Press

and hold the UNIT key and the POWER, HOLD key

simultaneously, then release POWER, HOLD key. First,

you will see an “n” display at the middle of the screen.

This means the sleep mode has been disabled. When

you release the UNIT key, 00000 and RPM are shown for

ready to the next measurement.

CONTACT MEASUREMENTS:

Select the tip (Convex or Concave), and install it on the

shaft of the adapter. See Diagram. Engage the tip with

the end of the rotate. Contact RPM - Used to measure

the speed of rotating Conveyers, Pumps, Motors, Gears,

Pulleys, Shafts, Flywheels and Elevators...

Display

LCD display

Time base

4.0Mhz Quartz Crystal

Sampling Time

1 sec (>60rpm) >1 sec. (10-60rpm)

Accuracy

0.04% ±2 digits

Operating Temperature

32 to 122°F (0 to 50°C)

Operating Humidity

Max. 80%RH.

Power Supply

9V battery

Power Current

Approx. 12mA DC

Power Consumption

2uA (Idle)

11mA (Measurement

SPECIFICATIONS

Test Range

Resolution

10,000 ~ 99999 RPM

0.001/0.01/0.1/1

1.000 ~ 9999.9 M/Min

0.0001/0.001/0.01/0.1

3.0000 ~ 30000 Ft/Min

0.0001/0.001/0.01/0.1

1.0000 ~ 10000 Yd/Min

0.0001/0.001/0.01/0.1