SPECIFICATIONS

Range:

–40° to 176°F / –40° to 80°C (probe)

14° to 176°F / –10° to 80°C (ambient)

Resolution: 0.1°

OPERATION

1. Remove the battery and re-insert it to set the clock on the unit. After the

segment test has been run, the minutes counter will flash. Set the

minutes by pressing the MIN/MAX button. Press and hold the MIN/MAX

button to increase the minute counter rapidly until the button is

released. Press the IN/DATE button to confirm the correct minute

setting.

2. The hour counter will begin flashing. Set the hour by pressing the

MIN/MAX button. Press and hold the MIN/MAX button to increase the

hour counter rapidly until the button is released. Press the IN/DATE

button to confirm the correct hour setting.

3. The month indicator will begin flashing. Set the month by pressing the

MIN/MAX button. Press and hold the MIN/MAX button to increase the

counter rapidly until the button is released. Press the IN/DATE button to

confirm the correct month setting. If no button is pressed for 15

seconds, the unit will be set and will begin recording temperature.

4. To select °F or °C, slide the switch located on the back of the unit to the

desired setting.

5. To switch the display between date and indoor temperature, press the

IN/DATE button. While in date mode, “DATE” will appear on the

display. While in ambient temperature mode, “IN” will appear on the

display.

6. To recall the stored memories, press the MIN/MAX button repeatedly

and the display will indicate the following:

Maximum outdoor temperature

Minimum outdoor temperature

Maximum indoor temperature

Minimum indoor temperature

The display will also show the corresponding date and time that the

MIN/MAX readings occurred. Press the MIN/MAX button again to return

to the current temperature mode.

7. To delete a minimum/maximum memory, press and the MIN/MAX

button until the desired memory is displayed. Press the IN/DATE button

and the displayed memory will be cleared. Repeat this process to clear

each desired memory.

BENCH STAND

The unit is supplied with a bench stand that is a part of the battery cover. To

use the bench stand, locate the small opening at the bottom of the unit.

Place your fingernail into the opening and flip the stand up. To close the

stand, simply snap it shut.

WALL MOUNTING THE UNIT

Set two screws into the wall at the desired location. Do not set the screw

flush to the wall; the heads of the screws will need to slip into the receptacles

on the back of the unit. Once the screws have been properly set, hang the

unit in place by sliding the receptacles on the back of the unit over the heads

of the screws.

ALL OPERATIONAL DIFFICULTIES

If this unit does not function properly for any reason, replace the battery with

a new high quality battery (see “Battery Replacement” section). Low battery

power can occasionally cause any number of “apparent” operational

difficulties. Replacing the battery with a new fresh battery will solve most

difficulties.

BATTERY REPLACEMENT

Erratic readings, faint readings, or no display are all indications that the

battery must be replaced. Remove the battery cover. Remove the

exhausted battery and replace with a new AAA alkaline battery. Replace the

battery cover making certain to run the probe cable through the slot on the

right or left bottom side of the battery cover. Upon initial installation of the

battery, the time and date will require setting. (See the “Operation” section.)

WARRANTY, SERVICE, OR RECALIBRATION

For warranty, service, or recalibration, contact:

CONTROL COMPANY

4455 Rex Road

Friendswood, Texas 77546 USA

Ph. 281-482-1714 Fax 281-482-9448

E-mail [email protected]

www.control3.com

Control Company is ISO 9001 Quality-

Certified by DNV and ISO 17025 accredited

as a Calibration Laboratory by A2LA.

Control Company Cat. No. 4105, 4305 & 4605

TRACEABLE

®

THERMOMETER WITH TIME/DATE MAX/MIN MEMORY INSTRUCTIONS

Advertising