8532-1.4_u9500-mos.pdf, S gas sensor – Det-Tronics MOS H2S Gas Sensor User Manual

Page 3

Advertising
background image

APPLICATION

The model U9500B Infiniti® Transmitter is designed for

use with Det-Tronics Metal Oxide Semiconductor (MOS)

sensors for detection of hydrogen sulfide gases and

vapors.

Gas concentrations are displayed in ppm on an

alphanumeric display. The transmitter provides a user

selectable isolated/non-isolated 4 to 20 milliampere

output signal that corresponds to the detected gas

concentration. An optional relay package is available to

provide contact outputs for alarm and fault conditions.

The electronics of the Infiniti transmitter is contained in an

explosion-proof housing. The sensor is coupled directly

to the Infiniti housing. The Infiniti offers non-intrusive

calibration by actuating a magnetic reed switch with a

hand-held magnet. It is not necessary to remove the

housing cover to actuate the magnetic reed switch.

Typical Infiniti applications include:

Confined spaces where gas/vapor leaks can

concentrate.

Known high risk leak locations.

General open area coverage.

FEATURES

User-friendly setup.

Non-intrusive calibration using the internal magnetic

reed switch, or an externally located pushbutton (not

included).

Automatic fault diagnostics and graphic message

annunciation.

Sensor sensitivity and end of sensor life indication.

Optional relay package provides three alarm relays

(high, low, and auxiliary) and one fault relay.

Variety of multi-port enclosure configurations

available.

SPECIFICATIONS

Transmitter
INPUT VOLTAGE—

24 vdc. Operating range is 16 to 32 vdc including

ripple.

POWER CONSUMPTION WITH SENSOR—

Infiniti with alarm relays and sensor connected, with 24

Vdc input voltage:

3 watts nominal, 5 watts maximum.

CURRENT OUTPUT—

Linear 4 to 20 ma output.

Maximum loop resistance is 600 ohms at 20 to 32 vdc.

Selectable isolated or non-isolated operation.

Factory set 2.0 ma output indicates unit is in Calibration

mode (field adjustable).

Less than 1.0 ma output indicates fault condition.

DISPLAY—

Eight character alphanumeric display indicates power

on, gas concentration, alarm and fault conditions. It also

enables field adjustment of alarm setpoints.

1.4

©

Detector Electronics Corporation 2007

8/07

95-8532

INSTRUCTIONS

U9500B210X Infiniti® Transmitter and

Metal Oxide Semiconductor (MOS)

H

2

S Gas Sensor