Heating on with shortpress and with settings, 3 operation and setting/adjustment, 30 21 °c – Eberspacher EasyStart Remote+ Operating instructions User Manual

Page 12: 21 °c, 60 min, 60 min 21 °c

Advertising
background image

12 | VehiCLe heATeRs – TeChniCAL DOCuMenTATiOn

3 OpeRATiOn AnD seTTing/ADjusTMenT

hEatiNg ON with shOrtprEss aNd with
sEttiNgs

press the

or

button to activate the mobile

unit. Following successful data transmission the start
display appears.

17:30

21 °C

shORTpRess button for less than 2 seconds; the

heATing submenu is displayed.

plEasE NOtE!

The following settings and confirmations (tempera-
ture setpoint and operating time) are always required.

seT TeMpeRATuRe seTpOinT – FOR AiR heATeRs
OnLy

if applicable, use the

or

button to set the

temperature setpoint.
temperature setpoint setting range:
8 °C – 36 °C in 1 °C increments,
46 °F – 97 °F in 1 °F increments.

21 °C

08:30

120 min

press the

button to confirm the temperature

setpoint.

seTTing The OpeRATing TiMe

if necessary, use the

or

button to set the

operating time.
Operating time setting range:
Min 10 – max 120 min in 1 min. increments, continu-
ous heating mode is possible for air heaters.

60 min

press the

button to confirm the operating time.

heater On.

60 min

21 °C

Display for air heaters in continuous heating mode
(factory setting).

21 °C

plEasE NOtE!

After switching on, “On” is displayed for 2 sec and
then the remaining operating time or

for air

heaters.
During heating mode it is possible to switch to another
menu item. under the VenTiLATiOn menu item, check
the operating time and if necessary adjust.
The changed operating time is offered again the next
time the system is started.

Advertising