Maintenance

37

y

To test the keypad, Press each key (except ESC and

ON). The value next to Keypad is hexadecimal and

corresponds to the key pressed. If the value does not

change for each key, refer to Troubleshooting in this

section.

y

Press the ESC key to stop the test.

Battery Replacement

The NiCad batteries need to be replaced when fully charged
batteries provide less than 2 hours operation. Carefully
follow the instructions below to replace the batteries.



NOTE: To retain trace data stored in nonvolatile RAM,

leave the AC mains adapter connected during battery

replacement.

1. Lay the Antenna Tester, display side down, on a clean

surface.

2. Using a small standard screwdriver, remove six screws

from the back cover.

3. Lift the back cover approximately two inches above the

front cover.

4. Flip the back cover in the direction of the arrow shown

below. To avoid disconnecting P2, (battery connector),

lay the back cover next to the front.

5. Remove the old batteries.
6. Install the new batteries checking the orientation of the

positive and negative terminals. Polarity is indicated on

the case, and in Figure 16.

7. Be sure P2 is connected and the shock strips are still in

place.

8. Place the back cover over the front cover making sure it

is properly seated.

CAUTION

Replace with only NiCad rechargeable AA

batteries, IEC code KR-15/51. Nominal

Voltage 1.2V; Capacity 650mAhr. Do not

install alkaline batteries.

Advertising