CALIBRATE HORIZONTAL

ENTER SETUP MODE

EXIT SETUP MODE

SET MONITOR SPEED

SET KEEP-OUT ZONES

SET TRAVEL LIMITS

CLEAR ALL

CALIBRATE VALVE

SET STOW POSITION

3

4

5

2

1

8

7

6

Typical Pumper Truck Install Guide:

3

Setup Mode

Press and hold

<Stream>

and

<Fog>

until

yellow

status

LED on controller

and blue status

LED on monitor

box turn on.

From a Joystick

Controller, press

and hold <Aux>

and

<Preset>

until LEDs turn

on.

Press and hold

<Stream>

and

<Fog> on the

panel mount and

<Aux>

and

<Preset> on the

joystick until the

status LEDs turn

off.

The

following

steps

are

optional (O).

Pressing

the

<Osc> button will

cycle through the

monitor

speed

options:

LEDs - Ver / Hor

0 - Fast / Fast

1 - Slow / Fast

2 - Fast / Slow

3 - Slow / Slow

Move monitor to

desired position,

then press <Fog>

and <Osc> at the

same time to

store a stow

position.

Stow

position

must be within

allowed limits of

travel.

Pressing <Open>

and <Close> at

the same time

will clear travel

limits, keep out

areas, and the

stow position.

Move monitor to

the left limit and

press <Close>.

Move monitor to

the right limit and

press <Open>.

Maximum Travel

limits will give

approx 175° of

travel from the

c a l i b r a t e d

horizontal forward

position in either

direction.

Lower Left:

Move to top/right

corner of the

lower left zone,

hold <Preset>,

press <Close>,

and release both.

Lower Right:

Move to top/left

corner of the

lower right zone,

hold <Preset>,

press, <Open>,

and release both.

This step is

required (R).

Aim monitor at

center

forward

“zero” position.

Hold <Preset>,

then press and

hold <Left> or

<Right>

until

status LED on

monitor blinks &

returns to solid.

Takes about a

second.

NOTE: You will

need to calibrate

the valve before

use. While you

are NOT in

setup

mode,

press and hold

<Preset>

and

<Close>

for

approximately 5

seconds.

The

valve

will

automatically

start to calibrate

itself.

98342030 Rev. Rel

(R)

(R)

(O)

(O)

(O)

(O)

SCORPION

OPEN

PRESET

PRESET

OPEN

AUX

OSC

OPEN

CLOSE

OSC

FOG

STREAM

PRESET

CLOSE

OPEN

CLEAR A

LL

CLOSE

STATUS

POWER

STATUS

POWER

R

L

Lower Left Zone:

Top right corner

Lower Right

Zone:

Top left corner

Right Travel Limit

Left Travel Limit

Lower Left

Zone

Lower Right

Zone

STREAM

STREAM

OSC

Advertising