4.

Leave the meter connected and go to the control side of the valve control module

and disconnect J10 and P10. Place a jumper between P10 contacts A (Black
wire/common ground) and B (Yellow wire/open signal). The meter should show
negative voltage. Jumping A (Black wire/common ground) to C (Orange wire/closed
signal) should result in positive voltage. (Once a jumper is connected the motor
voltage can only be maintained continuously for approximately 12 seconds before the
Valve Module cuts it off. This is a feature to prevent continuous motor stall in the
event of position sensor failure. If motor power does not cut off in both directions
within 10 to 14 seconds replace the valve control module.)

Passed; If the testing is successful move on to step 5.

Failed; If the testing is unsuccessful replace the valve control module. See Item 8

on the system layout drawing that matches your system voltage. Choose the p/n
for the Valve Control Module you need. Connect the new module, reconnect all
harnesses, and retest system starting at step 1.

5.

Reconnect J10 and P10 and disconnect P01 and J01. Place a jumper between

P01 contacts 16 (Black wire/common ground) and 18 (Yellow wire/open signal). The
meter should show (-) negative voltage. Jumping 16 (Black wire/common ground) to
17(Orange wire/closed signal) should result in (+) positive voltage. (Once a jumper is
connected the motor voltage can only be maintained continuously for approximately
12 seconds before the Valve Module cuts it off. This is a feature to prevent
continuous motor stall in the event of position sensor failure. If motor power does not
cut off in both directions within 10 to 14 seconds replace the valve control module.)

Passed; If test is successful check contacts in connectors P01 and J01. If they

appear damaged replace the component with the damaged contacts, reconnect
all harnesses, and retest starting at step 1. If they do not appear damaged move
on to step 6.

o If P01 contacts are damaged replace Joystick p/n 81172001 (Item 7) or

Switch Box 81122001 (Item 2).

o If P02 contacts are damaged replace Monitor control harness p/n 36787000

(Item 5).

Failed; If test is unsuccessful replace the control harness 36787000 (Item 5),

reconnect all harnesses, and retest system starting at step 1.