7 connecting the motor power, 8 connecting the main power to the guitar, Connecting the motor power – ElmoMC SimplIQ Digital Servo Drives-Guitar Evaluation Board User Guide User Manual

Page 39: Connecting the main power to the guitar

Advertising
background image

Whistle, Bell Guitar Evaluation Board User Guide

Combined Evaluation Board

MAN-EVLBRD-WHI-BEL-GUI (Ver. 1.401)

39

.10.7 Connecting the Motor Power

Connect the motor power cable to the M1, M2 and M3 terminals of the main power connector,

and the fourth wire to the PE (Protective Earth). The phase connection order is arbitrary

because the Composer will establish the proper commutation automatically during setup. If

several motors/drive combinations are designed to operate in an identical manner, we

recommend downloading the program into all the drives and connecting them in the same

way.

Notes for connecting the motor cables:

For best noise immunity, it is highly recommended to use a shielded (not

twisted) cable for the motor connection, such as a 4-wire shielded cable. The

gauge is determined by the actual current consumption of the motor.

Connect the shield of the cable to the closest ground connection at the motor

end.

Figure 18: AC Motor - Power Connection Diagram

.10.8 Connecting the Main Power to the Guitar

Connect the main power supply cable to the VPW+ and PR terminals of the main power

connector.

Power to the Guitar is provided by a 12 ~ 195 VDC source. A “smart” control-supply

algorithm enables the Guitar to operate with a power supply only, with no need for an

auxiliary 24 V supply. If backup functionality is required for storing control parameters in

case of power-outs, an external 24 VDC power supply can be connected, providing

maximum flexibility and optional backup functionality when needed.

Notes for connecting the DC power supply:

The source of the 12 ~ 195 VDC Main Power Supply must be isolated.

For best noise immunity, it is highly recommended to use twisted and

shielded cables for the DC power supply cable, such as a 3-wire shielded

cable. The gauge is determined by the actual current consumption of the

motor.

Connect the cable shield to the closest ground connection near the power

supply.

Advertising