.16.2 CANopen Communication

Notes for connecting the CANopen communication cable:

For “daisy-chain” connections use 26 or 28 AWG twisted pair shielded cables.

For best results, the shield should have aluminum foil and be covered by

copper braid with a drain wire.

Connect the shield to the ground of the host (PC). Usually this connection is

soldered internally inside the connector at the PC end. You can use the drain

wire to facilitate connection.

The Evaluation Board’s CANopen ports are

non-isolated.

The male RJ plug must have a shield cover.

Ensure that the shield of the cable is connected to the shield of the RJ plug.

The drain wire can be used to facilitate the connection.

Connect a termination 120-Ohm resistor at each of the two ends of the network cable.

There is an option for adding this resistor onboard (Thru-Hole or SMD):

P

i

n

Signal

Function

Pin Position

1

CAN_H

CAN_H busline (dominant high)

2

CAN_L

CAN_L busline (dominant low)

3

CAN_GND CAN ground

4

5

6

CAN_SHLD Shield, connected to the RJ plug cover

7

CAN_GND CAN Ground

8

Table

2-11: CANopen Cable - Pin Assignments