VIO Starter Addendum

Elmo Motion Control

Rev. 1/07

DIP – Switches

Switch

Function

ON

OFF

S1

CGC

CGC – ON (see section 3.3 in “VIO
Operating Manual)

CGC - OFF

S2

N/C

S3

CFM

CFM – ON (see section 3.2 in “VIO
Operating Manual)

CFM - OFF

S4

LM

LM – ON (see section 3.6 in “VIO
Operating Manual)

LM – OFF

S5

EN+

Setting S5 to ON applies +VCC voltage to
EN+ pin (If +VCC is applied to J4). Setting
both S5 & S6 will enable the amplifier
without an external signal.

No voltage is
applied to EN+

S6

EN

Setting S6 to ON connects VCCRET to EN-
pin.

No voltage is
applied to EN

Supply Voltage (+VCC & VCCRET

)

In order to operate the diagnostics LEDs and/or use the enable (EN) feature, an external
voltage must be applied to

+

VCC &

VCCRET terminals at J3. The DC supply

requirements are as follows:

Min. input voltage

5VDC

Max. input voltage

15VDC

Max. input current

13 mA

LED Indications

Refer to section 5 in the “VIO Operating Manual”

Function

Latch option

AOK

SO1

SO2

SO3

Amplifier OK (AOK)

N/A

ON

OFF

OFF

OFF

External disable

No

ON

ON

OFF

ON

Current limit

No

ON

OFF

OFF

ON

Short

Yes

OFF

ON

OFF

ON

Over temperature

Yes

OFF

OFF

ON

ON

Internal supplies
protection

No

OFF

ON

ON

OFF

Under voltage

No

OFF

ON

OFF

OFF

Over voltage

No

OFF

OFF

ON

OFF

Shunt request

No

ON

OFF

ON

OFF

Power Up Reset

No

OFF

OFF

OFF

OFF

Note: LEDs will light only if voltage is applied to +VCC and VCCRET.