SPECIFICATIONS

Model

No.

Capacity

Tons

Stroke

in (cm)

Effective

Area

in

2

(cm

2

)

Oil

Capacity

in

3

(cm

3

)

Weight

lbs (kg)

A

in.

(cm.)

B

in.

(cm.)

C

in.

(cm.)

BRP106C

10

6.00
(15,24)

2.32
(15,0)

13.8
(226,2)

35
(15,9)

23.13
(58,75)

--

1.38
(3,51)

BRP106L

10

6.00
(15,24)

2.32
(15,0)

13.8
(226,2)

29
(13,2)

22.19
(56,36)

28.19
(71,60)

1.18
(3,00)

BRP302

30

2.50
(6,35)

7.22
(46,6)

18.5
(303,2)

75
(34,0)

36.00
(91,44)

43.57
(110,7)

1.50
(3,81)

BRP306

30

6.00
(15,24)

7.22
(46,6)

43.3
(709,7)

106
(48,1)

37.95
(96,4)

43.95
(111,6)

1.50
(3,81)

INSTALLATION

Attach hose to coupler in

3

/

8

" NPT port. Connect mating coupler halves together hand

tight only. Using tools will damage the coupler.

CAUTION
Position hoses to avoid sharp bends, kinks, and sharp impacts from
falling objects, because they may cause wear or damage to the hose,
leading to premature failure.

OPERATION

Refer to the instruction sheet supplied with your pump for information on installing and
operating your pump.

1.

Check the oil level in the pump.

2.

Make sure all connections are tight and leak free.

3.

Remove air from the system by placing the cylinder at a lower level than the pump

with the coupler facing up. Cycle the cylinder several times until the motion is

smooth.