Enerpac VLP 10 ton User Manual

Page 3

Advertising
background image

3

Figure 1, 10-ton VLP

Trouble-shooting Guide

Problem

Possible Cause

Solution

Cylinder does not advance,
advances slowly or in
spurts

Cylinder advances, but
does not hold pressure

Cylinder does not retract,
retracts part way or
retracts more slowly than
normal

1. Oil level in pump reservoir is low
2. Release valve is open
3. Loose hydraulic coupler
4. Air trapped in system
5. Cylinder plunger binding

1. Leaking oil connection
2. Leaking seals
3. Internal leakage in pump

1. Release valve closed
2. Pump reservoir over filled
3. Loose hydraulic coupler
4. Air trapped in system
5. Cylinder retraction spring broken or

other cylinder damage

6. Additional tooling on cylinder too heavy

1. Add oil to pump
2. Close pump release valve
3. Check that all couplers are fully tightened
4. Remove air according to Section 4.2 Air Removal
5. Check for damage to cylinder. Have cylinder

serviced by a qualified hydraulic technician

1. Check that all connections are tightened
2. Locate leak(s) and have equipment serviced by

a qualified hydraulic technician

3. Have pump serviced by a qualified hydraulic

technician

1. Open pump release valve
2. Drain oil level to full mark
3. Check that coupler(s) are fully tightened
4. Remove air according to §4.2 Air Removal
5. Have cylinder serviced by a qualified hydraulic

technician

6. Remove tooling, check cylinder for damage

6” Fully Extended Plunger

(4) holes

1

RC106

Cylinder

2

P142

Pump

PATG1102N

Pump (European only)

3

GA4

Gauge Adaptor

4

HC9206

Hose

HC7206

Hose (European only)

Repair Parts List for VLP106

Item

Part Number

Description

Item

Part Number

Description