ERICO IP7947 Rail Girder Connection User Manual

Rail girder connection

Advertising
background image

Figure 1

Figure 2b

Single Cut

Bond

Bond

Double Cut

Bond

Tap Hole

Flare of

Terminal Against

Side of Mold

Figure 2a (Left

Hand Shown)

Figure 3

Steel Disk

Figure 4

Crucible

Cover

Starting

Material
Welding

Material

Steel Disk

Prior to making a connection, read and follow the full instruction sheet IPRPW, the full instruction sheet shipped with ERICO CADWELD

(IPX) and special instruction below.

Insert web bond into mold and push until flare of sleeve is against mold. This positions bond in weld cavity and terminal under center

1.

of tap hole correctly (See Fig. 2a and 2b).

Note: Fig. 2a - For double cut bonds, bond is interchangeable for left or right hand molds.

Fig. 2b - For single cut bond, angle of bond faces. upward. Left hand bond requires left hand mold; right hand bond requires right

hand mold.

Insert one steel disk, dished (concave) side up, in crucible to cover tap hole. See Fig. 3.

2.

Dump contents of one welding material container into crucible being careful not to upset disk. See Fig. 4.

3.

Tap welding material container to loosen starting material. Place a portion of the starting material on the top edge of mold at cover

4.

opening. Distribute the remaining starting material evenly over welding material and close cover. See Fig. 4.

Standing on field side of rail, ignite starting material on mold edge with flint igniter. Withdraw igniter quickly to prevent fouling.

5.

After approximately 10-15 seconds, open cover, release crucible hinge and break up the slag using mold cleaner tool, B136D.

6.

Unlock clamp and remove welder.

Dump the slag from the crucible and remove the slag from the tap hole using the end of the mold cleaner. Dump slag in the ballast,

7.

not on the ties.Check the mold for breakage or residual slag before proceeding with next bond.

Connection Preparation:

Dry the molds before the first connection of the day. Check bond terminals and disks for rust or corrosion. Clean and/or replace

accordingly.Check mold conditions (cracks, wear, chipped corners, etc.) Replace accordingly.

Welders should be clamped firmly to the rail but not so tight the clamps are difficult to close thus avoiding breaking or damaging the

molds.

Make sure the proper ERICO CADWELD welding material is being used. Use only F80 material for connection to rail (SB or PB

prefix part number; i.e., SB25). (Yellow Cap)

Place the disk in the mold, dished side up. Dump (don't pour) the welding material into mold. Always use mold cover and wear

safety equipment as specified. Stand upwind and on field side of rail when igniting the ERICO CADWELD welding material.

Rail Preparation:

Remove grease and oil from the rail before grinding. Remove moisture from the rail.

Only use grinding/cleaning wheels approved by ERICO for ERICO CADWELD applications. Avoid using wheels designed for cutting

as they can damage the rail.

®

®

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

TECHNICAL SUPPORT:

www.erico.com

IP7947_B

INSTRUCTION SHEET

SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

1 OF 1

© 2005, 2014

ERICO International Corporation

WARNING:

1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at

www.erico.com and from your ERICO customer service representative.

2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

3. All instructions must be completely followed to ensure proper and safe installation and performance.

4. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property

damage, serious bodily injury and death.

Rail Girder

Connection

Advertising
Table of contents