ERICO DSCL2 Surge Counter User Manual

Dscl2 surge counter

Advertising
background image

INSTRUCTION SHEET

WARNING

1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com

and from your ERICO customer

service representative.

2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.

4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death.

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are registered trademarks of ERICO International Corporation

TECHNICAL SUPPORT: IP8262_A 1 of 1 ©2013 ERICO International Corporation

www.erico.com


1. Preparation

DANGER:

Electrical shock or burn hazard. Qualified personnel should only
install this product. Failure to lockout electrical power during

installation or maintenance can result in fatal electrocution or severe burns.
Before making any connections to this electrical panel please ensure that
power has been removed from all associated wiring, electrical panels, and
other electrical equipment.

2. Introduction

DSCL2 consists of a LCD that shows count number and time/date
of event. Sensor is in the form of a Snap-on toroid core, connected
to counter with a twisted wire.

3. Quick Installation Overview

1. LCD screen is turned off by default to preserve energy. Turn it

on with the press of any button. The initial screen shows us
surge count (lower-right corner), the date (above) and the hour
(lower-left corner) of last surge.

2. Start the time and date setting routine by pressing the OK

button. While in time/date set routine, confirm by pressing OK
button or move back by pressing Set button. Numbers are
changed with UP (↑) and DOWN (↓) buttons. The number
being set is blinking.


3. When time/date is set an option for CLEARING ALL DATA

appears. Select option Yes or No with UP and DOWN arrows
and confirm it by pressing OK. WARNING! Once data is
cleared it can’t be retrieved.


Dimensions [mm]

Typical Installation


Battery Replacement

Technical Data

Impulse current min.

50A (8/20µs)

Impulse current max.

50kA (8/20µs)

Number of events logged

999

Average battery lifetime

> 4 years

Enclosure protection class

IP 20

Dimensions DIN 43880

2TE

Weight

150g

Temperature range

-20˚C….+70˚C

Storage temperature

-30˚C….+80˚C

Mounting EN 60715

35mm top-hat rail

Battery type (replaceable)

CR123A

DSCL2
Surge Counter