ERICO WTBRB Series Wind Turbine Receptor Assembly User Manual

Wtbrb series, Wind turbine receptor assembly

Advertising
background image

[1.97 in]

50mm

55 N-m[40 ft-lb]

2-3X

1

2

Receptor Termination Kit:

The list of parts contained in the termination kit includes:

Due to a policy of continuing product improvement, items in the kit may differ slightly from that listed.
List of Suggested Tools (Not Included)

ERICO part no. T313, card cloth brush (only needed if crimping connection).

Face spanner socket drive or wrench.

Procedure:

Apply 2-3 wraps of Loctite

®

QuickTape

®

249 medium strength threadlocker to the male stud of the receptor (#2) per

1.

the manufacturer's instructions. Install the receptor (#2) into the receptor block (#1). Using a face spanner wrench

(7/32" pin diameter, 1-1/4" diameter circle), tighten the receptor to 55 N-m [40 ft-lb]. See figure 1. (*Notice - Use of

liquid threadlocker is not permissible)

Figure 1: Installation of receptor.

Strip back the insulation from the end of the branch conductor to expose 50 mm [1.97 in] of bare conductor for

2.

connection to ERICO part no. LPAWXXT Y-Splice. The cable should look like Figure 2.

Figure 2: Exposed bare conductor (Figure may not represent the actual length of exposed cable)

Ensure that all strands and layers of the branch conductor are smooth and cylindrical, as they will not fit into the lug if

3.

distorted or frayed. In addition, remove any surface oxidation from the conductor using the T313 card cloth brush.

The use of an oxide inhibitor (such as Penetrox A-13) is recommended for the branch to root connection.

4.

QTY.

ITEM

DESCRIPTION

1

1

Receptor Assembly, terminated

1

2

Receptor disk

[1.97 in]

50mm

TECHNICAL SUPPORT

www.erico.com

IP8210_C

1 OF 1

INSTRUCTION SHEET

CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.

WARNING:

ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at

1.

www.erico.com and from your ERICO customer service representative.

ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.

2.

All instructions must be completely followed to ensure proper and safe installation and performance.

3.

Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property

4.

damage, serious bodily injury and death.

SAFETY INSTRUCTIONS:

All governing codes and regulations and those required by the job site must be observed.

Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.